1. Specification

 

Model

 

LP121HEM-Y8

 

Cooling Capacity

 

 

kW

3.28

 

3.37

 

 

 

Btu/h.

11300

 

11500

Heating Capacity ( for Heat Pump models)

 

kW

2.99

 

3.08

 

 

 

Btu/h.

10300

 

10500

Electric Heater capacity

 

 

kW

3.1

 

3.5

 

 

 

Btu/h.

10500

 

11900

Power Input

Cooling/Heating

 

W

1130 / 975

 

1150 / 995

Running Current

Cooling/Heating

 

A

5.6 / 4.8

 

5.2 / 4.4

Starting current

Cooling/Heating

 

A

-

 

-

Electric Heater Current

 

 

A

14.9

 

15.2

EER

 

 

W/W

2.84

 

2.84

 

 

 

Btu/h.W

10.0

 

10.0

COP

 

 

W/W

3.1

 

3.1

Power Supply

 

 

Ø / V / Hz

1 / 208 / 60

 

1 / 230 / 60

Power Factor

 

 

%

96.2/96.7

 

96.2/98.3

Air Flow Rate

Indoor,Max

 

m3/min(CFM)

11(390)

 

 

Outdoor,Max

 

m3/min(CFM)

-

 

 

Moisture Removal

 

 

l/h

1.5

 

Sound Level

Indoor,H/M/L

 

dB(A)±3

49/-/47

 

(SoundPressure,1m)

Outdoor,Max

 

dB(A)±3

63

 

Refrigerant & Charge

 

 

g(oz)

R22, 795(28.0)

 

Compressor

Type

 

Rotary(Non Tropical)

 

 

Model

 

QK164KBB

 

 

Motor Type

 

PSC

 

 

Oil Type

 

SUNISO 4GSI or NM56M

 

 

Oil Charge

 

cc

280

 

 

O.L.P Name

 

MRA 12124 - 12026

 

Fan

Type(In/Out)

 

Cross Flow Fan

 

Axial Fan

 

Motor Type(In/Out)

 

4 Poles

 

 

Motor Output(In/Out)

 

W

18.4/60

 

Power Supply Cable (Power Cord)

 

No.*mm2

3 * 2.1

 

Dimensions ( W * H * D)

 

 

mm

1066*406*505

 

 

 

 

inch

42*16*19-7/8

 

Net Weight

 

 

kg(lbs)

52.0(114.6)

 

Tool Code(Chassis)

 

 

 

YA

 

Features

Temperature Control

 

Thermistor

 

 

Energy Saver Mode

 

O

 

 

Prefilter(washable/anti-fungus)

 

O

 

 

Plasma Filter

 

-

 

 

 

Steps, Fan/Cool/Heat

 

2/2/2

 

 

Airflow Direction Control(up&down)

Manual

 

 

Airflow Direction Control(left&right)

-

 

 

 

Remote Controller Type

 

Wall Thermostat

 

 

Setting Temperature Range

 

Cooling

54˚F ~ 86˚F(12.2˚C ~ 30˚C)

 

 

 

 

Heating

54˚F ~ 86˚F(12.2˚C ~ 30˚C)

 

 

Auto Operation (Micom Control)

 

-

 

 

 

Panel Touch Type

 

Manual controls

 

 

Timer

 

-

 

 

 

Air Discharge

 

Rear

 

 

Air-Ventilation

 

O

 

 

Defrost Control

 

O

 

 

Hot Start

 

-

 

 

 

Look

 

L - Look

 

 

Cabinet Type(Chassis Type)

 

Slide In-Out

 

 

Special Function

 

Electric Heater

 

Note:

O : Applied, - : No relation

*For circuit breaker rating, please confirm to local standards wherever necessary. Some of functions are slightly different depending upon models.

The specification may be subject to change without prior notice for purpose of improvement.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 2 -

Only for training and service purposes

LGE Internal Use Only

 

Page 2
Image 2
LG Electronics LP121HEM-Y8 manual Specification, LGE Internal Use Only