Giant P200A-5100 Specifications Model P221A-3100/5100, Intermittent duty only, 1750 RPM+, Metric

Models: P200A-5100 P200A-3100

1 16
Download 16 pages 16.85 Kb
Page 7
Image 7
Specifications

Specifications

Model P221A-3100/5100

1750 RPM+

U.S.

(Metric)

 

 

Ratings

2.34 GPM @ 2000 PSI

(8.9 LPM @ 137 bar)

3450 RPM+

 

 

Ratings

4.2 GPM @ 2000 PSI

(15.9 LPM @ 137 bar)

Inlet Pressure

-4.35 to 140 PSI

(-0.3 to 10 bar)

RPM

Up to 3450 RPM

Plunger Diameter

0.71”

18mm

Stroke

0.28”

7.0mm

Temperature of Pumped Fluids

Up to 160o F

(71oC)

Inlet Ports (P221A-3100)

(2) 3/8” BSP

Inlet Ports (P221A-5100)

(2) 1/2” BSP

Discharge Ports

(2) 3/8" BSP

Shaft Rotation

Top of Pulley Towards Fluid End

Crankshaft Diameter

24mm

Key Width

8mm

Shaft Mounting

Right Side Facing Manifold

Weight

11 lbs. 11oz

(5 kg)

Crankcase Oil Capacity

7.5 fl.oz

(0.2 liter)

Extended Crankcase Oil Capacity

9.0 fl.oz

(0.3 liter)

Volumetric Efficiency @ 1750 RPM

0.95

Volumetric Efficiency @ 3450 RPM

0.87

Mechanical Efficiency @ 1750 RPM

0.86

+Positive inlet pressure required

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

NOTE:

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P221-3100/5100 HORSEPOWER

REQUIREMENTS

RPM

GPM

1000 PSI

1500 PSI

2000 PSI

250

0.3

0.2

0.3

0.5

500

0.7

0.5

0.7

0.9

1000

1.3

0.9

1.4

1.8

1450

1.9

1.3

2.0

2.7

1750

2.3

1.6

2.4

3.2

3000

3.7

2.5

3.8

5.0

3200

3.9

2.7

4.0

5.4

3450

4.2

2.9

4.3

5.8

*Intermittent duty only

HORSEPOWER RATINGS:

The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

HP = (GPM X PSI) / 1450