Giant P200A Specifications, Model P217A, P217A HORSEPOWER REQUIREMENTS, Special Note

Models: P200A

1 16
Download 16 pages 13 b
Page 3
Image 3
Specifications

 

Specifications

 

Volume

Model P217A

Up to 3.4 GPM

 

Discharge Pressure (Continuous)

Up to 2000 PSI

Discharge Pressure (Intermittent)

Up to 2320 PSI*

Inlet Pressure

14 to 140 PSI

RPM

Up to 3450 RPM

Plunger Diameter

18mm

Stroke

5.5mm

Temperature of Pumped Fluids

Up to 160o F

Inlet Ports

(2) 1/2" BSP

Discharge Ports

(2) 3/8" BSP

Shaft Rotation

Top of Pulley Towards Fluid End

Crankshaft Diameter

24mm

Key Width

8mm

Shaft Mounting

Right Side Facing Manifold

Weight

11 lbs. 11oz.

Crankcase Oil Capacity

7.5 fl.oz.

Extended Crankcase Oil Capacity

9.0 fl.oz.

Volumetric Efficiency @ 3450 RPM

0.88

Mechanical Efficiency @ 3450 RPM

0.86

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

NOTE:

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P217A HORSEPOWER REQUIREMENTS

RPM GPM 1000 PSI 1500 PSI 2000 PSI 2320 PSI*

1725

1.7

1.2

1.8

2.3

2.7

3000

3.0

2.1

3.1

4.2

4.8

3200

3.2

2.2

3.3

4.4

5.1

3450

3.4

2.3

3.5

4.7

5.4

*Intermittent duty only

SPECIAL NOTE:

The theoretical gallons per revolution (gal/rev) is 0.0009855.

To find specific outputs at various RPM, use the formula: GPM =0.0009855xRPM

HORSEPOWER RATINGS: The rating shown are the power

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

HP = (GPM X PSI) / 1450

3

Page 3
Image 3
Giant P200A operating instructions Specifications, Model P217A, P217A HORSEPOWER REQUIREMENTS, Special Note