Gibson Guitars 1550-07 GUS manual Function, MCK Position, Action, Remarks, Calibration, Mode

Models: 1550-07 GUS

1 64
Download 64 pages 4 Kb
Page 42
Image 42
Calibration

40

Function

Display LEDs

Calibration

C LED shines red

Mode

 

 

 

 

 

 

 

 

 

 

 

#

 

MCK Position

Pull MCK out and turn to C LED

Action

Access Calibration Mode by pressing the display for 3 seconds. The C LED will shine blue. Now turn the MCK to select your funda- mental frequency from the following list. (Note: while selecting your fundamental, pressing the display will toggle the red # LED on and off, and the other displayed LEDs will remain blue.)

# C LED shines red

Remarks

435Hz = C and E LED blue

436Hz = C and E LED blue, # LED red 437Hz = C and A LED blue

438Hz = C and A LED blue, # LED red 439Hz = C and D LED blue

440Hz = C and D LED blue, # LED red 441Hz = C and G LED blue

442Hz = C and G LED blue, # LED red 443Hz = C and B LED blue

444Hz = C and B LED blue, # LED red 445Hz = C and e LED blue

446Hz = C and e LED blue, # LED red

# Mode

Page 42
Image 42
Gibson Guitars 1550-07 GUS Function, MCK Position, Action, Remarks, Calibration, Mode, Display LEDs, C LED shines red