Operation

1.The pressure in the tank is controlled by the action of the pressure switch located under the pressure switch cover (2). When the set maximum pressure is reached the pressure switch activates and the motor is switched off. The pressure then decreases as the air is used by the connected tool until the set minimum is reached after which the pressure switch causes the motor to switch on again. The operator of the compressor should be well aware that during use of the compressor the motor will start and stop under the influence of the rising or falling pressure in the tank. The motor will start without any warning.

2.The maximum and minimum pressures are factory set and the operator should not try to change them.

3.You can connect an accessory to either the direct outlet valve (4) and/or the regulated outlet valve (7). The regulated outlet is the one on the left when you face the front of the compressor.

4.The pressure of the regulated outlet [as shown on the regulated outlet pressure gauge (8)] can be changed by turning the regulating knob (6). Rotate the knob clockwise to increase pressure and anti-clockwise to decrease pressure.

Note. To obtain the correct output reading on the regulated output gauge, the air must be flowing through the outlet.

The regulating valve should be adjusted and the gauge read with the outlet valve open and the air being discharged from the regulated outlet.

To increase the air pressure, rotate the regulating valve clockwise. To decrease the pressure, rotate the regulating valve anti-clockwise.

Note. If you do not allow the air to discharge while you are setting the regulator, the pressure as indicated on the regulated outlet gauge will be incorrect. This gauge ONLY indicates the correct pressure while air is being discharged from the outlet.

The discharge air from the right hand (opposite) outlet

(4)is not regulated and will discharge air at tank pressure. The gauge for this outlet (5) will show the correct pressure in the tank with or without the air being discharged.

5.On completion of the task, i.e. when you have finished using the compressor, or when you are leaving the compressor unattended, turn off the compressor in the following way:

Press down the on/off switch (3).

Wait for the pressurised air to bleed from the tank from the release valve under the pressure switch cover (2). Note. When you press the button down you should hear a short air discharge ( Approx 1/2 second)

Switch off the electrical power supply and remove the electrical plug.

Pull the ring on the safety valve (9) to ensure all the pressurised air is released from the tank, or open the drain cock to release the pressure from the tank.

Warnings.

1.Never attempt to remove any part of the compressor whilst the tank is under pressure.

2.Never attempt to remove any electrical component whilst the compressor is connected to the power supply. Switch off the power and remove the electrical plug.

3.Do not adjust the safety valve.

4.Do not use an electrical extension cable.

12

Page 12
Image 12
Global Machinery Company AC40L instruction manual Operation

AC40L specifications

Global Machinery Company's AC40L is a cutting-edge piece of equipment designed to meet the diverse needs of industries seeking efficiency, versatility, and reliability in their machinery. This model stands out in the realm of construction and heavy-duty equipment due to its advanced engineering and robust performance capabilities.

One of the primary features of the AC40L is its powerful engine. Designed with energy efficiency in mind, the engine delivers substantial torque, allowing it to handle a wide range of tasks from loading and unloading materials to maneuvering on challenging terrains. This robust powertrain not only enhances productivity but also minimizes operational downtime, making the AC40L a trusted choice for continuous work environments.

The AC40L is equipped with an advanced hydraulic system that allows for precise control during operations. This technology ensures that the machinery can perform intricate tasks with ease, significantly reducing the risk of errors or accidents. The system features a quick-attach interface, enabling operators to switch implements swiftly, adapting to various job requirements without hassle.

Ergonomics is a key consideration in the design of the AC40L. The operator cab is spacious and fitted with intuitive controls, allowing for comfortable and efficient operation. Enhanced visibility from the cab ensures that operators can always maintain awareness of their surroundings, which is critical in busy job sites. Additionally, the inclusion of climate control features ensures a comfortable working environment, effectively reducing operator fatigue.

Durability is another notable characteristic of the AC40L. Built with high-grade materials, the machinery is designed to withstand the rigorous demands of heavy-duty operations. Components are engineered for longevity, reducing maintenance needs and prolonging the lifespan of the equipment.

In terms of safety, Global Machinery Company has integrated advanced safety features, including rollover protection and stability control, which enhance operator confidence while working in potentially hazardous conditions.

Overall, the Global Machinery Company AC40L stands as a testament to innovative engineering, bringing together power, efficiency, and safety to meet the expectations of modern industries. This machine is not only an investment in productivity but also a commitment to the quality and reliability that Global Machinery Company is known for. Whether on a construction site, in landscaping, or involved in other heavy-duty applications, the AC40L proves to be an indispensable ally in achieving operational goals.