Global Machinery Company AC40L instruction manual Maintenance

Models: AC40L

1 16
Download 16 pages 27.55 Kb
Page 14
Image 14

 

Insufficient pressure or decreased

1. Motor running too slow

1.

Use authorised service centre to

 

outlet capacity

 

 

 

check and repair if necessary

 

 

2.

Dirty air filter cartridge

2.

Clean or replace the filter cartridge

 

 

3.

Leaking safety valve

3 – 7. Use authorised service centre to

 

 

4.

Leaking pipe

check and repair if necessary

 

 

 

 

 

 

 

5.

Damaged gasket

 

 

 

 

 

6.

Damaged or carbon coated valve

 

 

 

 

 

 

seat

 

 

 

 

 

7.

Damaged piston ring or cylinder

 

 

 

 

Excessive oil consumption

1. Oil level too high

1.

Maintain the oil at the correct level

 

 

2.

Hole in oil filling cap (14) blocked

2.

Check and clean

 

 

3.

Piston ring and/or cylinder worn or

3.

Use authorised service centre to

 

 

 

damaged

 

check and repair if necessary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance

1.After the first 10 hours of working, empty the crank case of oil and refill with clean oil by removing the crank case oil plug (left hand side of the crank case at the bottom)

Note. Use good quality compressor lubricating oil.

SAE30 or L-DAB 100 over 10°C

SAE10 or L-DAB 68 under 10°C

2.After each subsequent 500 hours of operation, again drain the oil and refill the crank case with clean oil.

3.After each day of operation, use the drain cock (11) under the tank to drain off any condensate.

4.Regularly check the air filter cartridge inside the air filter assembly (17) and replace the cartridge when necessary.

5.Check daily the operation of the safety valve. This check should be performed when the tank contains close to max pressure in the tank.

To check the valve, pressurise the tank, and pull the ring OUTWARDS on the safety valve.

Air should discharge from the valve.

Release the ring of the safety valve. When the ring is released the air discharge must stop.

Warnings.

Safety glasses must be worn when performing this test.

Do not have your face close to the safety valve when performing this test as air will discharge from the valve at a high force.

If the safety valve does not operate correctly in any way as described above, turn off the compressor immediately and have the compressor and safety valve checked and tested at an authorised Service centre.

DO NOT CONTINUE TO USE THE COMPRESSOR IN ANY WAY IF THE SAFETY VALVE DOES NOT WORK AS ABOVE.

14

Page 14
Image 14
Global Machinery Company AC40L instruction manual Maintenance