Global Machinery Company G25 Troubleshooting, Possible cause, Suggested remedy, Engine will

Models: G25

1 24
Download 24 pages 5.71 Kb
Page 18
Image 18
Troubleshooting

Troubleshooting

Trouble

Possible cause

Suggested remedy

 

 

 

Engine will

1. Low on fuel or oil content

1. Add fuel or oil

not start

 

 

 

 

2.

Ignition switch

2.

Turn to “ON” position

 

 

 

in “Off” position

 

 

 

 

 

 

 

 

3.

Faulty spark plug

3.

Replace spark plug

 

 

 

 

 

4.

Choke in wrong position

4. Adjust choke accordingly

 

 

 

 

 

 

5.

Unit loaded

5.

Remove load from unit

 

 

during start-up

 

 

 

 

 

 

 

 

6.

Spark plug lead

6.

Disconnect the spark plug lead and reattach spark plug lead.

 

 

loose/disconnected

 

 

 

 

 

 

 

 

7.

Unit may be flooded

7.

Leave the generator rest for 5-10 minutes and then try again,

 

 

 

 

following the instructions when doing so. Alternatively if the

 

 

 

 

choke lever is in full choke position (start), switch the choke to

 

 

 

 

the run position and try to re-start.

 

 

 

 

 

 

8.

Old Fuel

8.

Remove the existing fuel and replace with new.

 

 

 

 

AC power supply

1. Faulty receptacle

1.

Have service centre replace receptacle

- No electrical

2.

Is the green LED on

2.

YES - Try another appliance that is known to work.

output

 

with motor running

 

Reduce the load if required.

 

 

 

 

 

and no output?

 

NO - Organise for the unit to be serviced.

 

 

 

 

 

 

3.

Check to make sure

3.

If it is - reduce the load.

 

 

the red overload LED

 

 

 

 

is not on?

 

 

 

 

 

 

 

 

4.

Faulty power cord

4.

Replace cord

 

 

 

 

DC power supply

1. Circuit breaker kicked

1.

Yes – Depress the reset button, to rest the circuit breaker

- No electrical

 

out (DC only)

 

 

output

 

 

 

 

 

 

 

 

 

18

Page 18
Image 18