![Automatic voltage regulator (AVR)](/images/new-backgrounds/89896/8989623x1.webp)
Automatic voltage regulator (AVR)
This generator has been equipped with AVR technology which provides automatic voltage regulated power for continuous uninterrupted stable power supply.
The AVR maintains a regulated AC output and reacts substantially quicker to rapid surges in voltage, therefore, preventing the possibility of damage to the generator and attached equipment.
Preparing the generator
It is important to check the generator before you commence operating the unit.
IMPORTANT. Ensure that the engine has oil. When leaving the factory, this generator has NO OIL in the engine.
Note. The engine will not start if the generator has no oil.
Checking the engine fuel
Checking the engine oil
The motor of this generator is not filled with oil.
Prior to starting the motor ensure the crank case is filled with SAE #30 4 stroke oil.
Damage to the motor is not covered under warranty if the motor is run without oil.
1.Before checking or refilling oil, be sure the generator is put on a stable and level surface, ensuring the engine has been switched OFF.
2.Remove the oil filler cap (7) by rotating the cap anti- clockwise and inspect to see the oil level.
3.If the oil level is below the lower level line, refill with SAE #30 4 stroke oil to the upper level line.
Note. Do not screw in the oil filler cap (7) when checking oil level, simply insert and pull the cap straight out.
1. | Switch off engine by turning the ignition switch (10) to |
| the ‘off’ position. |
2. | Check the fuel level by viewing the fuel level gauge (3). |
3. | If the fuel is low, remove the fuel cap (2) by turning |
| anticlockwise. |
4. | Check to ensure the fuel filter screen is inside the fuel |
| filter neck. |
5. | Pour the unleaded fuel from an approve fuel container |
| into the fuel tank (1). Because fuel expands, DO NOT |
| FILL to the lip of the tank. |
6. | Replace fuel cap (2) and turn clockwise to lock. |
WARNING. |
4.If the oil is contaminated or has discoloured, ensure you change the oil. Refer to the ‘Engine oil replacement’
section for instructions.
Note. This motor is fitted with a low oil sensor. If the oil level is too low the motor will stop operating or the motor will not start. It is advised to
check the oil level each time the generator is used.
Oil filler cap (oil gauge)
Upper level
Lower level
• Do not refill fuel tank (1) while engine is running or is hot. |
•Check to ensure that the fuel drain (16) has been tightened and that fuel is not leaking.
•Be careful not to admit dust, dirt, water or other foreign objects into the fuel.
•Wipe off spilt fuel thoroughly before starting engine.
•Ensure you DO NOT fuel the generator in close proximity to any open flames.
Connecting the battery |
| |
A | ||
Note. Before using the key | ||
| ||
start function of the generator |
| |
you must connect the battery to |
| |
the generator. |
| |
1. Firmly take hold of both |
| |
plugs and insert one into |
| |
the other until they ‘click’ |
| |
into place (Fig. A). |
| |
|