Global Machinery Company GEN2300ES Troubleshooting, Possible cause, Suggested remedy, tripping

Models: GEN2300ES

1 24
Download 24 pages 39.74 Kb
Page 21
Image 21
Troubleshooting

Troubleshooting

Trouble

Possible cause

Suggested remedy

 

 

 

Engine will not start

1. Low on fuel or oil content

1. Add fuel or oil

 

2.

Ignition switch in “Off” position

2.

Turn the ignition to the ‘START’ position

 

 

 

 

if using key start, or ‘ON’ position if

 

 

 

 

manually starting.

 

 

 

 

 

 

3.

Faulty spark plug

3.

Replace spark plug

 

 

 

 

 

4.

Choke in wrong position

4. Adjust choke accordingly

 

 

 

 

 

 

5.

Fuel shut-off valve in closed position

5.

Open fuel shut-off valve

 

 

 

 

 

 

6.

Unit loaded during start-up

6.

Remove load from unit

 

 

 

 

 

7.

Spark plug wire loose

7. Attach wire to spark plug

 

 

 

 

No electrical output

1. Faulty receptacle

1.

Have service centre replace receptacle

 

2.

Circuit breaker kicked out

2.

Depress and reset

 

 

 

 

 

 

3.

Worn Brushes

3.

Have service centre replace brushes

 

 

 

 

 

 

4.

Faulty power cord

4.

Replace cord

 

 

 

 

Repeated circuit breaker

1. Overload

1.

Reduce load

tripping

 

 

 

 

2.

Faulty cords or equipment

2. Check for damaged, bare, or frayed

 

 

 

 

wires on equipment. Replace.

 

 

 

 

Generator overheating

1. Generator overloaded

1.

Reduce load

 

2.

Insufficient ventilation

2.

Move to adequate supply of fresh air

 

 

 

 

 

21

Page 21
Image 21