Global Machinery Company PB26D Stopping the blower, Blowing, Use of the petrol blower, Air filter

Models: PB26D

1 12
Download 12 pages 29.03 Kb
Page 9
Image 9
Stopping the blower

Stopping the blower

Stop the engine by pressing the off button (12) and holding it for 2 seconds.

Blowing

Start the blower engine, as previously described. Hold the blower firmly about 10 - 20 cm

from the ground and move it in a sweeping motion from left to right, directing the debris to the desired location.

Use low throttle settings when clearing lightweight materials from around lawns or shrubbery.

Use medium to higher throttle settings to move lightweight grass or leaves from driveways or paths.

Use full throttle when moving heavy loads such as dirt or snow.

IMPORTANT. Blower noise increases at higher throttle settings. Always use the lowest throttle setting required to get the job done.

Never operate the blower unless it is properly assembled and in good working condition.

Never operate the blower without a properly functioning muffler and spark arrestor installed.

Use of the petrol blower

The GMC petrol blower can efficiently move a wide variety of debris ranging from grass clippings to gravel. As a general rule try to operate the blower at the lowers throttle setting necessary to get the job done.

Prior to use of the blower ensure you have read and understood this instruction manual.

Ensure you are wearing suitable clothing and also safety equipment like safety glasses, ear protection and a mask if necessary.

Maintenance

WARNING. Before performing any maintenance on this blower, stop the engine and disconnect the spark plug wire.

Checking the spark plug

Check the spark plug every 10 - 15 hours of use.

Note. There is a replacement spark plug included with the blower.

1.Remove the spark plug cover.

2.Use the spark plug wrench to remove the spark plug, by turning it counter-clockwise.

3.Clean and adjust the spark plug gap to 0.6 - 0.7mm. Replace any damaged or visibly worn plug with a CHAMPION RCJ6Y,

NGK BPM9A or equivalent spark plug.

4.Install the spark plug finger tight in the cylinder head, then tighten it firmly with the spark plug wrench.

Air filter

The air filter should be checked approximately every 10 hours of use, or more frequently in dusty areas.

1.Loosen the air filter cover retaining screw (16), and remove the cover and filter element.

2.Inspect the element. If the element is distorted or damaged, replace it with a new one.