Avenger Owner’s Manual | Revised 06/04/08 |
DIAGNOSTICS SYSTEM
TruCharge Battery Display Diagnostics
NOTE: When the display is down to two (2) bars, the batteries must be charged before driving your Avenger.™
Fault | Description | Bars | Self Help Guide |
Type |
|
|
|
1 | Show if reaching low | 1 bar | The battery needs charging or there is a |
| voltage |
| bad connection to the battery. Check all |
|
|
| connections between the controller and |
|
|
| the battery. If the connections are good, |
|
|
| try charging the battery. |
2 | Motor disconnected | 2 bars | There is a bad connection to the motor. |
|
|
| Check all of the connections between |
|
|
| the motor and the controller. |
3 | Motor wiring fault | 3 bars | The motor has a short circuit to a |
|
|
| battery connection. Contact your service |
|
|
| agent. |
4 | Parking brake off | 4 bars | The freewheel switch or manual brake |
|
|
| disengagement mechanism is operated. |
|
|
| Check the position of the switch or |
|
|
| lever. |
5 | Not used | 5 bars | Not used. |
6 | Inhibit active | 6 bars | The controller is being inhibited from |
|
|
| driving; this may be caused because the |
|
|
| battery charge is still connected or the |
|
|
| seat is not in the proper driving position. |
7 | Throttle potentiometer | 7 bars | A throttle fault is indicated. Make sure |
| fault |
| the throttle is in the rest position before |
|
|
| switching on the scooter. |
8 | Possible controller fault | 8 bars | A controller fault has been indicated. |
|
|
| Contact your service agent. |
9 | Solenoid brake fault | 9 bars | There is a bad connection to the parking |
|
|
| brake. Check all connections between |
|
|
| the parking brake and the controller. |
10 | High battery voltage | 10 bars | An excessive voltage has been applied |
|
|
| to the controller. This is usually caused |
|
|
| by a poor battery connection. Check all |
|
|
| connections between the battery and |
|
|
| controller. |
WARNING: DO NOT OPERATE THE SCOOTER IF THE BATTERY IS NEARLY DISCHARGED. FAILURE TO COMPLY WITH THIS CONDITION MAY LEAVE THE USER STRANDED IN AN UNSAFE POSITION.