General

This manual covers only the installation of the remote heat pump. See the unit specification sheet for information regarding accessories.

SHIPPING AND HANDLING

Units are securely packed in shipping containers ap- proved by the International Safe Transit Association. Check the carton upon arrival for external damage. If damage is found, file a request in writing for inspection by the carrier agent immediately. The carrier is responsible for making prompt inspection of damage and for a thorough investiga- tion of each claim. The distributor or manufacturer will not accept claims from dealers for transportation damage. If no damage is found, carefully remove all shipping material and properly dispose of it.

Keep the unit as upright as possible. Laying the unit on its side or top could cause equipment damage.

LOCATION AND CLEARANCES

This unit is for outdoor installation only. The unit cannot be completely enclosed. At least one side must be unre- stricted. Refer to Figure 1 for clearances from the sides and top of the unit to walls and other objects.

NOTE: These minimum clearances do not guarantee adequate service access. Sufficient clearances for servic- ing the unit(s) must be provided.

If installing two or more units at the same location, allow at least 24 inches between the units when using the 6”-12”- 12” guidelines in Figure 1. The space between two units may be reduced to 12” if the clearances in Figure 1 are increased to 12”-24”-24”.

MINIMUM CLEARANCES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12"

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIDE VIEW

Figure 1

DO NOT locate the unit:

Directly under a vent termination for a gas appliance.

Within 3 feet of a clothes drier vent.

Where the refreezing of defrost water would create a hazard.

Where water may rise into the unit.

Where the noise would prove to be a nuisance to the customer (i.e. windows, patios, decks, etc.)

DO locate the unit:

With the bottom of the unit at least three inches above the maximum expected snow accumulation level.

In accordance with the minimum clearances described in Figure 1.

To minimize the length of refrigerant piping required.

To provide adequate service clearances.

On a level concrete pad (or other sturdy, weather resistant platform).

Isolated from the building structure to avoid transmis- sion of vibrations.

NOTE: Short runs of refrigerant piping are better than long runs. Locate the unit to provide safe access for future maintenance and service. If possible, discuss unit location with the owner before proceeding.

ROOFTOP INSTALLATIONS

Before installing this unit on a roof, ensure that the roof will support the weight of the unit, its platform, and the service personnel. For the unit weight, see the outdoor unit specification sheet (all weights are approximate). If there is doubt about the adequacy of the roof, contact a qualified architect or structural engineer before installing the unit. Ensure the unit is placed on a level, weather-resistant platform.

APPLICATION NOTE

For proper performance, the indoor equipment and duct- work must be adequate for moving about 400 CFM of indoor air for every ton of cooling capacity to be installed. If they are not, modify the ductwork or indoor equipment accordingly.

Refrigerant Piping

REFRIGERANT VAPOR AND LIQUID LINE SIZING

See unit “Specification Sheet” for the required vapor and liquid line tubing sizes. The listed sizes in the specification sheet are suitable for line lengths of fifty feet or less and indoor coil elevations of no more than forty feet above or below the outdoor unit. NOTE: Unit performance is affected by vapor line tubing size. A larger than required vapor line tubing inhibits oil return to the unit. A smaller than required vapor line tubing size decreases unit perfor- mance by up to 10%. If a run of more than fifty feet is required, contact your Amana distributor for assistance.

Check the indoor coil liquid and vapor line diameter. A bushing or coupling may be needed to match with the line

3 3

Page 3
Image 3
Goodman Mfg RHA**B*D installation instructions General, Refrigerant Piping