MBVC BLOWER SPECIFICATIONS
H |
W |
D |
3 1/4 |
C |
5 1/8 |
(3) KNOCKOUTS |
1.125 |
1.375 |
1.750 |
.875 KNOCKOUT |
(2 PLACES) |
5 |
6 1/2 |
MBVC1200/1600/2000
MODEL | Physical Information |
|
| Dimensions, inches (mm) | Shipping | ||||
Blower Wheel | Blower Motor | 1 |
| 1 | W | H | D | Weight | |
| (D x W) | (HP) | MCA | MOP |
| lbs.(kg) | |||
|
|
|
|
|
|
|
|
|
|
MBVC1200 | 10X8 | 1/2 | 4.3 | 15 |
| 17½ | 26 | 21 | 72 |
| (445) | (660) | (533) | (32.6) | |||||
|
|
|
|
|
| ||||
MBVC1600 | 10X8 | 3/4 | 6.3 | 15 |
| 21 | 30 | 21 | 82 |
| (533) | (762) | (533) | (37.2) | |||||
|
|
|
|
|
| ||||
MBVC2000 | 11X10 | 3/4 | 5.8 | 15 |
| 24½ | 30 | 21 | 94 |
| (622) | (762) | (533) | (42.6) | |||||
|
|
|
|
|
|
1Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate for MCA and MOP with approved accessory heaters installed.