Product Specifications

Schematic Wiring Diagrams

Low-Voltage Control Wiring Diagram

Component Codes

CM

Outdoor Fan Motor

COMP

Compressor

C

Contactor

DC

Defrost Control

LDVR

Low-Voltage Defrost Relay

CH

Crankcase Heater

IO

Internal Overload

LP

Low-Pressure Control

HP

High-Pressure Control

OT

Outdoor Thermostat (Optional)

FC

Fan Capacitor

DFT

Defrost Thermostat

RVC

Reversing Valve Coil

HVDR

High-Voltage Defrost Relay

AST

Anti-Short Cycle Timer

Line-Voltage Power Wiring Diagrams

380/415, 50 HZ, 3 PH

220/240, 50HZ, 1 PH

CPKF36-5, CPKF48-5, CPKF60-5 & CPKF61-5

CPKF24-2, CPKF36-2 & CPKF48-2

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2012 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.