SS-GSCC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65ºF

 

 

75ºF

 

 

 

85ºF

 

 

95ºF

 

 

105ºF

 

 

 

115ºF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet Bulb Temperature

 

 

 

 

 

 

 

 

 

 

IDB

Airflow

59

63

67

71

59

63

 

67

71

59

 

63

67

71

59

63

67

 

71

59

63

67

71

59

 

63

67

71

 

 

MBh

57.8

59.1

63.1

67.5

56.5

57.7

 

61.6

65.9

55.1

 

56.3

60.2

64.3

53.8

55.0

58.7

 

62.8

51.1

52.2

55.8

59.6

47.3

 

48.4

51.7

55.2

 

 

S/T

0.90

0.85

0.69

0.52

0.94

0.88

 

0.72

0.53

0.96

0.90

0.73

0.55

1.00

0.93

0.76

 

0.57

1.00

0.97

0.79

0.59

1.00

1.00

0.79

0.59

 

 

∆T

25

24

21

17

25

24

 

21

17

25

24

21

17

26

25

21

 

17

25

24

21

17

23

23

20

16

 

1913

kW

3.79

3.88

4.03

4.18

4.13

4.23

 

4.39

4.55

4.43

4.54

4.71

4.89

4.70

4.81

4.99

 

5.18

4.92

5.04

5.23

5.43

5.12

5.24

5.44

5.65

 

 

Amps

13.9

14.2

14.7

15.2

15.0

15.4

 

15.9

16.5

16.3

16.7

17.2

17.9

17.4

17.8

18.4

 

19.1

18.5

19.0

19.6

20.4

19.6

20.1

20.8

21.6

 

 

Hi PR

149

160

169

176

167

180

 

190

198

190

204

216

225

216

233

246

 

256

243

262

276

288

269

289

305

318

 

 

Lo PR

61

65

70

75

64

68

 

74

79

67

71

77

82

70

74

81

 

87

73

78

85

91

76

81

88

94

 

 

MBh

56.1

57.4

61.3

65.5

54.8

56.0

 

59.9

64.0

53.5

54.7

58.4

62.5

52.2

53.4

57.0

 

60.9

49.6

50.7

54.2

57.9

45.9

46.9

50.2

53.6

 

 

S/T

0.86

0.81

0.66

0.49

0.89

0.84

 

0.68

0.51

0.92

0.86

0.70

0.52

0.95

0.89

0.72

 

0.54

0.98

0.92

0.75

0.56

0.99

0.93

0.76

0.56

 

 

∆T

26

25

22

17

26

25

 

22

18

27

25

22

18

27

26

22

 

18

26

25

22

18

25

24

20

16

80

1700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

3.76

3.85

3.99

4.14

4.09

4.19

 

4.35

4.51

4.39

4.50

4.67

4.84

4.65

4.77

4.95

 

5.13

4.88

5.00

5.18

5.38

5.07

5.20

5.39

5.59

 

 

Amps

13.8

14.1

14.5

15.1

14.9

15.2

 

15.7

16.3

16.1

16.5

17.1

17.7

17.3

17.7

18.3

 

19.0

18.4

18.8

19.4

20.2

19.5

19.9

20.6

21.4

 

 

Hi PR

147

158

167

174

165

178

 

188

196

188

202

213

223

214

230

243

 

254

241

259

273

285

266

286

302

315

 

 

Lo PR

60

64

70

74

63

68

 

74

78

66

70

77

82

69

74

80

 

86

73

77

84

90

75

80

87

93

 

 

MBh

51.8

52.9

56.6

60.5

50.6

51.7

 

55.2

59.1

49.4

50.5

53.9

57.6

48.2

49.2

52.6

 

56.2

45.8

46.8

50.0

53.4

42.4

43.3

46.3

49.5

 

 

S/T

0.83

0.78

0.63

0.47

0.86

0.81

 

0.66

0.49

0.88

0.83

0.67

0.50

0.91

0.86

0.70

 

0.52

0.95

0.89

0.72

0.54

0.95

0.90

0.73

0.54

 

 

∆T

27

26

22

18

27

26

 

22

18

27

26

22

18

27

26

23

 

18

27

26

22

18

25

24

21

17

 

1488

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

3.65

3.74

3.88

4.02

3.98

4.08

 

4.23

4.38

4.27

4.37

4.53

4.70

4.52

4.63

4.81

 

4.99

4.74

4.86

5.04

5.23

4.92

5.05

5.24

5.43

 

 

Amps

13.4

13.7

14.1

14.7

14.5

14.8

 

15.3

15.9

15.7

16.1

16.6

17.2

16.8

17.2

17.8

 

18.4

17.9

18.3

18.9

19.6

18.9

19.4

20.0

20.8

 

 

Hi PR

143

154

162

169

160

172

 

182

190

182

196

207

216

208

223

236

 

246

233

251

265

277

258

278

293

306

 

 

Lo PR

58

62

68

72

62

65

 

71

76

64

68

74

79

67

71

78

 

83

70

75

82

87

73

77

85

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

58.8

60.0

62.8

67.0

57.5

58.6

 

61.3

65.4

56.1

57.2

59.9

63.9

54.7

55.8

58.4

 

62.3

52.0

53.0

55.5

59.2

48.2

49.1

51.4

54.8

 

 

S/T

0.95

0.91

0.83

0.67

0.98

0.95

 

0.86

0.69

1.00

0.97

0.88

0.71

1.00

1.00

0.91

 

0.73

1.00

1.00

0.94

0.76

1.00

1.00

0.95

0.77

 

 

∆T

27

26

25

22

27

27

 

25

22

27

27

25

22

26

27

25

 

22

25

25

25

22

23

24

23

20

 

1913

kW

3.82

3.92

4.06

4.22

4.17

4.27

 

4.43

4.60

4.47

4.58

4.75

4.93

4.74

4.86

5.04

 

5.23

4.97

5.09

5.28

5.48

5.16

5.29

5.49

5.70

 

 

Amps

14.0

14.3

14.8

15.4

15.1

15.5

 

16.0

16.6

16.4

16.8

17.4

18.1

17.6

18.0

18.6

 

19.3

18.7

19.2

19.8

20.6

19.8

20.3

21.0

21.8

 

 

Hi PR

150

162

171

178

168

181

 

191

200

192

206

218

227

218

235

248

 

259

246

264

279

291

271

292

308

322

 

 

Lo PR

61

65

71

76

65

69

 

75

80

67

72

78

83

71

75

82

 

87

74

79

86

92

77

81

89

95

 

 

MBh

57.1

58.2

61.0

65.0

55.8

56.9

 

59.6

63.5

54.5

55.5

58.1

62.0

53.1

54.2

56.7

 

60.5

50.5

51.4

53.9

57.5

46.7

47.7

49.9

53.2

 

 

S/T

0.90

0.87

0.79

0.64

0.94

0.90

 

0.82

0.66

0.96

0.93

0.84

0.68

0.99

0.96

0.86

 

0.70

1.00

0.99

0.90

0.73

1.00

1.00

0.90

0.73

 

 

∆T

28

27

26

22

28

28

 

26

23

28

28

26

23

28

28

26

 

23

27

28

26

23

25

26

24

21

85

1700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

3.79

3.88

4.03

4.18

4.13

4.23

 

4.39

4.55

4.43

4.54

4.71

4.89

4.70

4.81

4.99

 

5.18

4.92

5.04

5.23

5.43

5.12

5.24

5.44

5.65

 

 

Amps

13.9

14.2

14.7

15.2

15.0

15.4

 

15.9

16.5

16.3

16.7

17.2

17.9

17.4

17.8

18.4

 

19.1

18.5

19.0

19.6

20.4

19.6

20.1

20.8

21.6

 

 

Hi PR

149

160

169

176

167

180

 

190

198

190

204

216

225

216

233

246

 

256

243

262

276

288

269

289

305

318

 

 

Lo PR

61

65

70

75

64

68

 

74

79

67

71

77

82

70

74

81

 

87

73

78

85

91

76

81

88

94

 

 

MBh

52.7

53.7

56.3

60.0

51.5

52.5

 

55.0

58.6

50.3

51.2

53.7

57.2

49.0

50.0

52.3

 

55.8

46.6

47.5

49.7

53.1

43.1

44.0

46.1

49.1

 

 

S/T

0.87

0.84

0.76

0.62

0.90

0.87

 

0.79

0.64

0.93

0.89

0.81

0.65

0.96

0.92

0.83

 

0.68

0.99

0.96

0.86

0.70

1.00

0.97

0.87

0.71

 

 

∆T

28

28

26

23

29

28

 

27

23

29

28

27

23

29

29

27

 

23

29

28

27

23

27

26

25

21

 

1488

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

3.68

3.78

3.91

4.06

4.01

4.11

 

4.27

4.43

4.31

4.41

4.58

4.75

4.56

4.68

4.85

 

5.03

4.78

4.90

5.08

5.28

4.97

5.10

5.29

5.49

 

 

Amps

13.5

13.8

14.3

14.8

14.6

14.9

 

15.4

16.0

15.8

16.2

16.8

17.4

16.9

17.3

17.9

 

18.6

18.0

18.5

19.1

19.8

19.1

19.6

20.2

21.0

 

 

Hi PR

144

155

164

171

162

174

 

184

192

184

198

209

218

210

226

238

 

248

236

254

268

279

261

280

296

309

 

 

Lo PR

59

63

68

73

62

66

 

72

77

65

69

75

80

68

72

79

 

84

71

76

83

88

74

78

85

91

IDB: Entering Indoor Dry Bulb Temperature

 

 

 

 

 

 

 

 

 

Shaded area reflects AHRI (TVA) conditions

 

 

 

 

Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW = Total system power