Install the Air Flow Switch
NOTE: The GFB Interface Module Kit does not include an air flow switch (AFS). The AFS is supplied with the gun flush box kit. Install the AFS in the interface module as follows.
1.Each gun flush box kit includes one air flow switch (AFS). The GFB interface module can accommo- date 1 or 2 air flow switches. Install the switch(es) in the right side of the enclosure. See FIG. 3.
1 AFS is part of gun flush box kit; not included with GFB Interface Kit.
AFS#1 1
AFS#2
1
TI14281a
FIG. 3. Install Air Flow Switch (two shown)
Installation
2.Connect the wires from AFS#1 to the right side of the terminal strip (12) pins 1 (+) & 2
12 21
TI14279a
FIG. 4. Connect Air Flow Switch to Terminal Strip
3.If using a second gun flush box, connect the wires from AFS#2 to the right side of the terminal strip (12) pins 3 (+) & 4
313212A | 5 |