Maximum Working Pressure

Technical Data

3:1 Ratio President Pumps, Models 220–561, 220–564, 237–222, 237–223, and 239–819

Maximum Working Pressure

3.4 MPa, 34 bar (500 psi)

Wetted Parts

 

Air Operating Range . 0.1–1.1 MPa, 1.4–11 bar (20–166 psi)

Model 220–561

. Carbon Steel, Stainless Steel,

Air Consumption

. See Performance Chart

Ultra-High Molecular Weight Polyethylene, Leather, PTFE r

Continuous Duty Delivery

. 35.3 liter/min (9.3 gpm)

Model 220–564

Chrome-Plated Stainless Steel,

Pump Cycles Per Liter (gallon) . . . .

. . . . . . . . . . . . . 1.7 (6.25)

Ultra-High Molecular Weight Polyethylene, Leather, PTFE r

Maximum Recommended Pump Speed . . . . . 60 cycles/min

Model 237–223

. Carbon Steel, Stainless Steel,

Air Inlet

. . . . . . . . . . . . . 1/2 npt(f)

Ultra-High Molecular Weight Polyethylene, PTFE r

Fluid Inlet

. . . . . . . . . . . 1–1/2” npt(f)

Model 237–222

Chrome-Plated Stainless Steel,

Fluid Outlet

. . . . . . . . . . . . . . . . 1” npt

Ultra-High Molecular Weight Polyethylene, PTFE r

 

MPa, BAR PSI

 

 

 

CPM

 

 

 

 

 

 

 

 

12

25

37

50

62

74

87

 

 

 

 

2.8, 28

400

 

 

m3/min

 

 

 

 

 

 

 

 

CFM

 

2.45, 24.5

350

 

 

 

 

 

 

 

 

70

1.96

 

PUMP OUTLET PRESSURE

2.1, 21

300

 

A

 

 

 

 

 

 

60

1.68

AIR CONSUMPTION

1.7, 17

250

 

 

 

 

 

 

 

50

1.40

 

 

 

 

 

 

 

A

1.4, 14

200

 

B

 

 

 

 

 

40

1.12

 

 

 

 

 

 

 

 

150

 

 

 

 

 

 

B

 

 

1.05, 10.5

 

 

 

 

 

 

 

30

0.84

 

C

 

 

 

C

 

 

0.7, 7

100

 

 

 

 

 

 

20

0.56

0.35, 3.5

50

 

 

 

 

 

 

 

 

10

0.28

 

 

 

 

 

 

 

 

 

 

 

 

0

0

2

4

6

8

10

12

14

0

 

 

 

GPM

 

 

 

l/min

 

8

15

23

30

38

46

54

 

 

 

PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)

A0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.