Graco 220-569 Viscount I+ Pumps, Models 236-601and, Viscount I+ Pumps, Models 236-605and, 3789

Models: 220-569

1 48
Download 48 pages 51.17 Kb
Page 46
Image 46
Viscount I+ Pumps, Models 236–601 and 236–602

Technical Data

Viscount I+ Pumps, Models 236–601 and 236–602

Maximum Working Pressure . . . . . 3.1 MPa, 31 bar (450 psi) Maximum Hydraulic Working Pressure . . 10.3 MPa, 103 bar (1500 psi)

Continuous Duty Delivery . . . . . . . . . . 36.5 liter/min (9.6 gpm) Pump Cycles Per Liter (gallon) . . . . . . . . . . . . . . . . . 1.64 (6.2) Maximum Recommended Pump Speed . . . . . 60 cycles/min Maximum Hydraulic Motor Fluid Temperature . 54_C (134_F)

Hydraulic Fluid Inlet . . . . . . . . . . . . . . . . . . . . . . 3/4”, (37_ flare) Hydraulic Fluid Outlet . . . . . . . . . . . . . . . . . . . . 7/8”, (37_ flare) Wetted Parts

Model 236–601 . . . . . . . . . Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE ￿ Model 236–602 . . . . . . . . Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE ￿

 

MPa, BAR

PSI

 

 

CPM

 

 

 

 

 

 

19

37

56

74

GPM

l/min

 

 

3.4, 34

500

 

 

 

 

 

5

19.0

 

 

 

450

 

 

 

 

 

 

 

3.15, 31.5

 

 

 

 

 

 

 

HYDRAULIC OIL CONSUMPTION

PUMP OUTLET PRESSURE

2.8, 28

400

A

 

 

 

 

4

15.2

2.45, 24.5

350

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.1, 21

300

B

 

 

 

 

3

11.4

1.7, 17

250

 

 

 

 

 

 

1.4, 14

200

 

 

 

 

 

2

7.6

1.05, 10.5

150

C

 

 

 

 

 

 

0.7, 7

100

 

 

 

 

1

3.8

 

 

 

 

 

0.35, 3.5

50

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

GPM 0

3

6

9

12

15

 

 

 

l/min

11

23

34

46

57

 

 

 

PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)

A10.3 MPa, 103 bar (1500 psi) hydraulic oil pressure

B6.9 MPa, 69 bar (1000 psi)

hydraulic oil pressure

C3.4 MPa, 34 bar (500 psi) hydraulic oil pressure

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating hydraulic pressure (MPa/bar/ psi):

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with selected fluid outlet pressure curve (black urves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

To find Motor Hydraulic Oil Consumption (liter/min or gpm) at a specific delivery (liter/min or gpm) :

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with hydraulic oil consumption curve (gray curve). Curve slopes from right to left. Follow right to scale and read hydraulic oil consumption.

Viscount I+ Pumps, Models 236–605 and 236–606

Maximum Working Pressure . . . . . 2.1 MPa, 21 bar (300 psi)

 

Hydraulic Fluid Inlet . . . . . . . . . . . . . . . . . . . . . . 3/4”, (37_ flare)

Maximum Hydraulic Working Pressure

. . 10.3 MPa, 103 bar

 

Hydraulic Fluid Outlet

. . . . . . . . . . . . . . . . . . . . 7/8”, (37_ flare)

 

 

 

 

 

(1500 psi)

 

Wetted Parts

 

 

Continuous Duty Delivery . . . . . . . . . 55.6 liter/min (14.7 gpm)

 

Model 236–605 . . . . . . . . . Carbon Steel, Stainless Steel,

Pump Cycles Per Liter (gallon)

. . . . . . . . . . . . . . . . . . 1.1 (4.1)

 

Ultra-High Molecular Weight Polyethylene, Leather, PTFE ￿

Maximum Recommended Pump Speed

. . . . .

60 cycles/min

 

Model 236–606 . . . . . . . . Chrome-Plated Stainless Steel,

Maximum Hydraulic Motor Fluid Temperature . 54_C (134_F)

 

Ultra-High Molecular Weight Polyethylene, Leather, PTFE ￿

 

 

 

 

 

CPM

 

 

 

 

 

A 10.3 MPa, 103 bar (1500 psi)

 

 

 

 

 

 

 

 

 

 

hydraulic oil pressure

 

MPa, BAR

PSI

12

25

37

49

 

 

 

 

 

GPM

l/min

 

B 6.9 MPa, 69 bar (1000 psi)

 

2.1, 21

300

 

 

 

 

 

 

A

 

 

 

 

6

22.8

 

hydraulic oil pressure

 

 

 

 

 

 

 

 

C 3.4 MPa, 34 bar (500 psi)

 

 

 

 

 

 

 

 

 

 

 

1.7, 17

250

 

 

 

 

 

 

 

HYDRAULIC OIL CONSUMPTION

hydraulic oil pressure

PUMP OUTLET PRESSURE

 

 

 

 

 

5

19.0

To find Outlet Pressure (MPa/bar/psi) at

 

 

 

 

 

 

 

 

 

a specific delivery (liter/min or gpm) and

1.4, 14

200

 

 

 

 

 

4

15.2

operating hydraulic pressure (MPa/bar/

B

 

 

 

 

psi):

 

 

 

 

 

 

 

 

1. Locate desired delivery along bottom

1.05, 10.5

150

 

 

 

 

 

3

11.4

of chart.

 

 

 

 

 

2. Read vertical line up to intersection

 

 

 

 

 

 

 

 

 

with selected fluid outlet pressure

 

100

 

 

 

 

 

 

 

curve (black urves). Curve slopes

0.7, 7

C

 

 

 

 

2

7.6

from left to right. Follow left to scale

 

 

 

 

 

and read outlet pressure.

0.35, 3.5

50

 

 

 

 

 

1

3.8

To find Motor Hydraulic Oil

 

 

 

 

 

Consumption (liter/min or gpm) at a

 

 

 

 

 

 

 

 

 

specific delivery (liter/min or gpm) :

 

0

 

 

 

 

 

 

 

1. Locate desired delivery along bottom

 

 

 

 

 

 

 

0

 

 

 

 

3

6

9

12

15

 

 

of chart.

 

GPM 0

 

 

 

2. Read vertical line up to intersection

 

l/min

11

23

34

46

57

 

 

 

with hydraulic oil consumption curve

 

 

 

 

(gray curve). Curve slopes from right

 

 

 

 

 

 

 

 

 

 

 

 

 

PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)

 

 

 

to left. Follow right to scale and read

 

 

 

 

 

hydraulic oil consumption.

46

3￿7￿8￿9

 

 

 

 

 

 

 

 

 

 

Page 46
Image 46
Graco 220-569 manual Viscount I+ Pumps, Models 236-601and, Viscount I+ Pumps, Models 236-605and, Technical Data, 3789