Service
Reconnecting the Displacement Pump
WARNING
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
1.Orient the pump’s fluid outlet to the air motor’s air inlet as was noted in step 3 under Disconnecting the Displacement Pump. Position the displace- ment pump (107) on the tie rods (102). See Fig. 4.
NOTE: If you removed the tie rods (102) from the air motor (101) or air motor adapter plate, reinstall them using an 11 mm wrench. Torque the rods to
2.Screw the locknuts (106) onto the tie rods (102) and torque to
3.Place the coupling nut (104) on the displacement rod (1), then place the collars (105) in the nut. Screw the nut onto the connecting rod (103) loosely. Hold the connecting rod flats with an adjustable wrench to keep it from turning. Using an adjustable wrench, torque the nut to
4.Using a torque wrench in the square hole of the supplied wrench (113), torque the packing nut (2) to
5.Mount the pump and reconnect all hoses. Recon- nect the ground wire if it was disconnected during repair. Turn on the air and run the pump slowly.
6.Fill the packing
101
108
103
102 2
105
1104
1
2 3
113 | 7 | 106 | 4 |
107
1Torque to
Torque to
2
3Torque to
4Torque to
01059
Fig. 4
308200 13