Graco 222839 Series A dimensions Technical Data 222907 President, 308200, 1.008, 0.672, 0.336

Models: 222839 Series A 222907 Series A

1 30
Download 30 pages 8.87 Kb
Page 27
Image 27
1.008

Technical Data (222907 President)

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

1.Locate fluid flow rate along bottom of chart.

2.Follow vertical line up to intersection with selected fluid outlet pressure curve.

3.Follow left to scale to read fluid outlet pressure.

A100 psi (0.7 MPa, 7 bar) air pressure

B70 psi (0.49 MPa, 4.9 bar) air pressure

C40 psi (0.28 MPa, 2.8 bar) air pressure

psi

Fluid Outlet Pressure

PRESSURE

MPa, bar

 

 

 

 

5000

 

 

 

 

35, 350

A

 

 

 

4000

 

 

 

 

 

 

 

28, 280

 

 

 

 

3000

 

 

 

 

OUTLET

B

 

 

 

21, 210

 

 

 

 

 

 

 

2000

 

 

 

 

14, 140

C

 

 

 

FLUID

 

 

 

1000

 

 

 

 

 

 

 

7, 70

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

gpm 0.00

0.15

0.30

0.45

0.60

liters/minute

0.57

1.14

1.70

2.28

FLUID FLOW (TEST FLUID: 1900 CENTIPOISE OIL)

To find Pump Air Consumption (m#/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1.Locate fluid flow rate along bottom of chart.

2.Read vertical line up to intersection with selected air consump- tion curve.

3.Follow left to scale to read air consumption.

A100 psi (0.7 MPa, 7 bar) air pressure

B70 psi (0.49 MPa, 4.9 bar) air pressure

C40 psi (0.28 MPa, 2.8 bar) air pressure

 

scfm

 

Air Consumption

 

 

 

 

 

 

 

m#/min

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.840

 

 

 

 

 

 

 

 

 

 

 

CONSUMPTION

 

 

 

 

 

 

 

 

A

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.672

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.504

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

AIR

0.336

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.168

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gpm 0.00

0.15

0.30

0.45

0.60

liters/minute

0.57

1.14

1.70

2.28

FLUID FLOW (TEST FLUID: 1900 CENTIPOISE OIL)

 

psi

Fluid Outlet Pressure

PRESSURE

MPa, bar

 

4000

 

28, 280

A

 

3000

 

21, 210

 

OUTLET

2000

B

14, 140

1000

C

FLUID

 

7, 70

 

0

 

 

 

AIR CONSUMPTION

scfm m#/min

36

1.008

24

0.672

12

0.336

0

Air Consumption

A

B

C

gpm 0.00

0.15

0.30

0.45

0.60

liters/minute

0.57

1.14

1.70

2.28

FLUID FLOW (TEST FLUID: 11,000 CENTIPOISE SEALANT)

gpm 0.00

0.15

0.30

0.45

0.60

liters/minute

0.57

1.14

1.70

2.28

FLUID FLOW (TEST FLUID: 11,000 CENTIPOISE SEALANT)

308200 27

Page 27
Image 27
Graco 222839 Series A, 222907 Series A dimensions Technical Data 222907 President, 308200, 1.008, 0.672, 0.336