Installation

Mounting the Pump

Models 226013, 226018, 244637

1. Mount the pump support bracket (86). (FIG. 4)

86

FIG. 4

2.Remove inductor plate nut (11 or 24), locking ring (8 or 23) and o-ring (9). (FIG. 5)

3.In order, slide inductor plate nut (11 or 24), locking ring (8 or 23) and o-ring (9) on pump riser tube. (FIG. 5)

4.Adjust the inductor plate on the pump so that the pump intake is 0.12 in. (3.2 mm) above the mount- ing base.

5.Tighten the lock nut (11 or 24) securely. Continue with Step 4 below.

 

DETAIL

pump riser

8 or 23

 

 

tube

 

 

11 or 24

2 or 22

pump intake

 

slots

 

0.12” (3.2 mm)

FIG. 5

NOTE: The full length of the pump intake slots must be just below the bottom of the inductor cone.

Model 204490

Refer to FIG. 6 for Steps 1-3 below.

1.Lubricate the o-ring (20) in the inductor plate (18) with light, waterproof grease. (FIG. 6)

2.Mount the pump on the pump support (64) so the fluid outlet faces front.

3.Guide the pump intake valve as far as possible into the inductor plate, then tighten the set screws (19). Continue with Step 4 below.

18

20

19

 

 

 

FIG. 6

306556S

7

Page 7
Image 7
Graco 244637, 204490 important safety instructions Mounting the Pump, Models 226013, 226018