Technical Data

Models 239140 46:1 Ratio SST President Performance Chart

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

1.Locate desired flow along bottom of chart.

2.Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.

To find Pump Air Consumption (m#/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1.Locate desired flow along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.

A100 psi (0.7 MPa, 7 bar) air pressure

B70 psi (0.49 MPa, 4.9 bar) air pressure

C40 psi (0.28 MPa, 2.8 bar) air pressure

President 46:1 Fluid Outlet Pressure

President 46:1 Air Consumption

 

psi

cycles per minute

 

 

 

scfm

cycles per minute

 

 

 

MPa, bar

21

41

62

82

 

m#/min

21

41

62

82

 

5000

 

40

 

 

 

 

 

 

 

 

 

 

PRESSUREFLUID

35, 350

A

 

 

 

CONSUMPTIONAIR

1.12

 

 

 

A

4000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

28, 280

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

0.84

 

 

 

 

 

3000

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

21, 210

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

C

 

 

 

 

0.56

 

 

 

 

 

14, 140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

C

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.28

 

 

 

 

7,70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

0

 

 

 

 

 

gpm 0.0

0.2

0.4

0.6

0.8

 

gpm 0.0

0.2

0.4

0.6

0.8

liters/minute

0.8

1.5

2.3

3.0

liters/minute

0.8

1.5

2.3

3.0

 

FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)

 

FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)

307619 23