Graco 239888, 239877, 239887 warranty Do not use slots in shovel tube to tighten or loosen tube

Models: 239888 239877 239887

1 18
Download 18 pages 23.58 Kb
Page 10
Image 10

Displacement Pump Service

Using nut (63), torque the pump cylinder (59)

1 to the extension tube (64) at 45 to 55 ft-lb (61-75 N-m).

3 Torque the shovel rod (58) to the piston (52) at 25 to 30 ft-lb (34 to 41 N-m).

4

Torque the piston (52) to the extension rod

(57) at 25 to 30 ft-lb (34-41 N-m).

 

5

1 59

60

56

4 52

64

 

62

 

 

 

 

61

 

 

63

57

3

58

53

 

 

54

 

66

 

 

67

CAUTION:

Do not use slots in shovel tube to tighten or loosen tube.

Fig. 3

10 308883