Graco 234401, 24M178 important safety instructions Installation, Shop Air Piping Layout

Models: 234401 24M178

1 12
Download 12 pages 59.23 Kb
Page 3
Image 3

Installation

Installation

1.Before installing air line components, blow out the pipe line to remove debris. Be sure air to the regula- tor is clean. Erratic operation or loss of regulation is usually caused by dirt in the regulator.

2.Install the Air Drying System as close as possible to the equipment it serves. Use template 289185, pro- vided, to position system.

3.Install air shut-off valve 288798 upstream from the air system to isolate it for service.

4.Install system so air flows through filters in the direc- tion noted on top of filter.

5.A minimum 1/2 in. npt piping is recommended. Avoid using too many fittings, couplings, etc., which will restrict air flow.

Shop Air Piping Layout

Main Air Line

3/4 in. (19 mm) minimum

1-1/4 in. (32 mm) optimum

Compressor

 

 

 

 

 

 

 

 

 

 

Coalescer

 

 

Main Air

 

 

 

 

 

Shut-off Valve

 

 

 

Flexible hose

 

 

 

 

 

 

 

between compressor

1

5-

 

 

 

 

 

and stand pipe

 

20

f

 

 

 

 

 

 

t. (

 

 

 

 

 

 

 

4.

 

 

 

 

 

 

 

6-6.

 

 

 

 

 

 

 

1

m)

 

 

 

 

 

 

 

Slop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

es do

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

w

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e

co

m

m

 

 

n

an

d

 

a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e

 

 

 

 

 

 

 

w

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ay

 

 

 

 

 

 

 

 

(1

5.

24 m)

nd

e

d

4 in. (

11

 

 

 

 

 

 

 

 

g

al

7

 

 

 

 

 

 

 

 

 

 

va

 

m

m)

 

 

 

 

 

 

 

 

 

 

 

 

niz

 

 

dr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

ed

pi

pe re

 

op

in 50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

com

 

ft

(13 mm) drops

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

men

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

de

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d)

 

Air Control unit or Air Filter

 

 

 

Membrane air

 

 

 

Ball Valve

drying system

1

 

 

 

6

8 1

 

 

 

2

 

Air

Drain

 

 

 

Leg

OR

 

 

Filter

Desiccant air

 

 

 

 

 

 

drying system

Drain Valve

Main Air Line stand pipe should not be smaller than compressor outlet size.

A minimum of 25 ft. (7.62 m) from compressor to first filter outlet is required to cool air [50 ft. (15.24 m) optimum]

309921N

3

Page 3
Image 3
Graco 234401, 24M178 important safety instructions Installation, Shop Air Piping Layout