Graco 257500, 258699 Terminal Connections, Connections Contacts Reading Diagnosis

Models: 257500 258699

1 24
Download 24 pages 4.01 Kb
Page 5
Image 5

Kettle Gas Safety Valve, Kettle Temperature Control, and Kettle Thermopile Diagnosis

Kettle Gas Safety Valve,

Kettle Temperature Control, and

Kettle Thermopile Diagnosis

The gas safety valve, temperature control and thermo- pile can be checked by using a millivolt meter. Before checking, make certain all electrical connections are clean and tight.

Terminal Connections

3

TH

TP TH

1

TP

Connect millivolt meter to appropriate terminals (see

ti14524a

 

2

 

Terminal Connections).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status of

 

 

 

 

 

 

 

 

Temperature

Desired

 

 

 

 

 

Part(s) to Be

Terminal

Control

Meter

 

 

 

 

Step

Checked

Connections

Contacts

Reading

Diagnosis

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Gas safety

2 and 3

Closed

Greater than

If mV reading > 100 mV and the automatic valve (main

 

valve

 

 

100 mV

burners) does not come on, replace the gas safety valve.

 

 

 

 

 

If mV reading < 100mV, proceed with diagnostic steps 2

 

 

 

 

 

and 3.

 

 

 

 

 

 

 

 

 

 

2

Temperature

1 and 2

Closed

Less than

If reading > 80 mV:

 

 

 

control

 

 

80 mV

• Clean and tighten electrical connections at tempera-

 

 

 

 

 

 

 

 

 

 

ture control and gas safety valve.

 

 

 

 

 

 

 

• Check valve to make sure wires are in good condi-

 

 

 

 

 

tion. Replace as required.

 

 

 

 

 

 

 

• Rapidly change temperature setting on temperature

 

 

 

 

 

control to see if cycling cleans the contacts.

 

 

 

 

 

 

 

If the preceding fails to give mV reading < 80 mV, replace

 

 

 

 

 

temperature control.

 

 

 

 

 

 

 

 

 

 

3

Gas safety

1 and 2

Open

Greater than

If mV reading < 325 mV:

 

 

 

valve magnet

 

 

325 mV

• Clean and tighten all electrical connections.

 

 

 

and

 

 

 

 

 

 

 

 

 

• Adjust pilot burner to increase millivolt output (see

 

thermopile

 

 

 

 

 

 

 

page 11).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the preceding fails to give mV reading > 325 mV, replace

 

 

 

 

 

thermopile.

 

 

 

 

 

 

 

Check valve magnet after obtaining correct mV output for

 

 

 

 

 

thermopile:

 

 

 

 

 

 

 

• Ignite pilot burner only and allow the mV reading to

 

 

 

 

 

stabilize.

 

 

 

 

 

 

 

• Shut pilot burner (turn gas safety valve knob OFF).

 

 

 

 

 

Note the mV reading where magnet drops out.

 

 

 

 

 

 

 

If magnet unlocks at mV reading < 120 mV, the magnet is

 

 

 

 

 

OK. NOTE: When magnet unlocks a click can be heard

 

 

 

 

 

and mV reading may fluctuate slightly.

 

 

 

 

 

 

 

 

 

 

 