Kettle Temperature Control Calibration

Kettle Temperature Control Calibration

To Check Kettle Temperature Control Calibration:

1.Move Thermolazerto an area with no wind.

2.Turn temperature control to 400° F (204° C).

3.Agitate material for 4 to 5 minutes.

4.After control has reached steady state temperature and burners do not cycle more than once per min- ute, insert remote calibrated temperature probe in material and directly adjacent kettle temperature control probe.

5.Compare temperature of remote calibrated temper- ature probe to temperature setting on temperature control.

6.If the temperature control setting is lower than the remote calibrated temperature setting on tempera- ture probe, turn adjusting screw clockwise. Every 1/4 in. turn will change temperature 35° F (19.4° C).

ti14523a

7.If the temperature control setting is higher than the remote calibrated temperature probe, turn adjusting screw counterclockwise--every 1/4 in. turn will change temperature 35° F (19.4° C).

8.Recheck calibration by turning temperature control to 410° F (210° C) and repeat steps 3-7.

Temperature Control Replacement

When replacing temperature control, keep in mind that the temperature probe is an integral part of the assem- bly. Do not make any sharp bends in the capillary tubing. Bends should be 0.25 in. (0.64 cm) in radius or greater.

Be sure to seal capillary tubing with high temperature mortar at kettle outlet.

ti14557a

Thermometer Replacement

Thermometer can not be removed from ThermoLazerwithout damaging thermometer probe. If probe end is frozen in material, heat material and remove until mate- rial level is lower than thermometer probe.