Graco 262893 important safety instructions Dispensing and Spraying

Models: 262893

1 22
Download 22 pages 832 b
Page 12
Image 12

Operation

8.Cycle the solvent flush ball valves on and off inde- pendently several times to be sure both sides are thoroughly flushed. Continue flushing until clean sol- vent dispenses.

Dispensing and Spraying

1. Close solvent inlet valves.

ti19269a

9.Turn off solvent pump air supply.

10.Hold the metal part of the gun firmly to a grounded metal pail with lid in place. Trigger gun until all fluid pressure is relieved.

11.Engage trigger lock.

12.Close solvent inlet valves.

ti20095a

ti20095a

2. Open mix manifold inlet ball valves.

ti20128a

3.Ensure sprayer is in “spray” mode and push the green START button.

4.Disengage spray gun trigger lock.

ti19265a2

5.Hold the metal part of the gun firmly to a grounded metal pail with a lid to avoid splashing. Trigger the gun until mixed coating material is evident and flushing fluid is gone.

6.Proceed to spraying.

12

3A2988B

Page 12
Image 12
Graco 262893 important safety instructions Dispensing and Spraying