Repair

Repair

Follow Pressure Relief Procedure, page 10, when you stop spraying and before cleaning, checking, ser- vicing, or transporting equipment. Read warnings in your sprayer manual.

NOTICE

Be sure to label all fluid parts A or B when disas- sembling them. Doing so prevents interchanging resin and hardener parts during reassembly, which will contaminate the materials and the fluid path through the equipment.

Color-coded chemically resistant tape may be used to label the parts. Use blue for resin and green for hardener.

Check Valves

When replacing material check valves or solvent check valves, reinstall with proper flow direction.