308491 11
Service
Fig. 10
1
22
15
04736
6. Loosent he setscrew (15). Pull the fluid housing (22)
away from the gun body (1). See Fig. 10.
04734
Fig. 11
16
17
7. While supporting the spring guide (16) to prevent
bending the needle, loosen the setscrews (17).
Remove the spring guide (16). See Fig. 11.
Fig. 12
2c 2d
2e
03974
8. Remove the needle (2c). Unscrew the seal retainer
(2d). Remove the seal (2e). See Fig. 12.
Cleaning
Clean all parts and cavities thoroughly with a compat-
ible solvent. Dry with a rag or compressed air. Replace
any parts that are worn or damage.
Reassembly
Fig. 13
1
3
2Lipsof s eal must face into housing
Grease inner cavity of housing
Torqueto 30--40 in-lb (3.4--4.5N.m)
22
2e
2d
1
2
3
03975
1. Lightly grease the inner cavities of the fluid hous-
ing (22). Install the small seal (2e) so the lips face
into the fluid housing cavity. Install the seal retainer
(2d) and torque to 30--40in- lb (3.4--4.5N.m). S ee
Fig. 13.