Setup

Setup

1.Apply thread sealant to the male threads of the air needle valve (48) and the quick disconnect fitting (49) and install. See FIG. 4

3.Use labels (70) provided to identify the appropriate pump for your material. See FIG. 5.

1Apply thread sealant

1

48

1

49

WLD

FIG. 4

2. Apply thread sealant to the male outlet fitting (not supplied) and insert into the outlet port. See FIG. 5.

1 Apply thread sealant

1

1

FIG. 5

FIG. 6

4.Lubricate the bung adapter inside diameter and mounting threads. Ensure the gasket is in place and screw the bung adapter (51) securely into the bung- hole of the drum. Insert the pump through the adapter and lock it in place. See FIG. 7.

2Lubricate threads

51

2

FIG. 7

311882T