Technical Data
Technical Data
.
5:1 Fire-Ball® 300 Pumps
| US | Metric |
Maximum fluid working pressure | 900 psi | 6.2 MPa, 62 bar |
|
|
|
Fluid pressure ratio | 5:1 | |
|
|
|
Air pressure operating range* | 40 to 180 psi | 0.28 to 1.2 MPa, 2.8 to 12 bar |
|
|
|
Maximum air consumption | 13 ft3/minute for first gpm | 0.096 m3/minute for first lpm |
| pumped at 100 psi up to 8 addi- | pumped at 0.7 MPa, 7 bar up to |
| tional ft3/min for each additional | 0.058 additional m3/min for each |
| gpm with pump operated within | additional lpm with pump oper- |
| recommended range | ated within recommended range |
|
|
|
Pump cycles per gallon (liters) | 30 | 7.9 |
Recommended speed for optimum pump life | 70 cycles per minute | |
Maximum recommended pump speed | 130 cycles per minute 5 gpm | 130 cycles per minute 19 lpm |
|
|
|
Wetted Parts | Steel, aluminum, | |
|
| |
Sound pressure level (measured at 1 meter | 77.8 dB(A) | |
from unit) |
|
|
|
| |
Sound power level (tested in accordance with | 85.6 dB(A) | |
ISO |
|
|
|
|
|
Approximate weight | 17 lb | 7.7 kg |
|
|
|
Loctite® is a registered trademark of the Loctite Corporation.
(m3/min)
14 | 306518ZAC |