Graco 306518ZAC Technical Data, tional ft3/min for each additional, additional m3/min for each

Models: 306518ZAC

1 16
Download 16 pages 54.25 Kb
Page 14
Image 14
Technical Data

Technical Data

Technical Data

.

5:1 Fire-Ball®300 Pumps

 

US

Metric

Maximum fluid working pressure

900 psi

6.2 MPa, 62 bar

 

 

 

Fluid pressure ratio

5:1

 

 

 

Air pressure operating range*

40 to 180 psi

0.28 to 1.2 MPa, 2.8 to 12 bar

 

 

 

Maximum air consumption

13 ft3/minute for first gpm

0.096 m3/minute for first lpm

 

pumped at 100 psi up to 8 addi-

pumped at 0.7 MPa, 7 bar up to

 

tional ft3/min for each additional

0.058 additional m3/min for each

 

gpm with pump operated within

additional lpm with pump oper-

 

recommended range

ated within recommended range

 

 

 

Pump cycles per gallon (liters)

30

7.9

Recommended speed for optimum pump life

70 cycles per minute

Maximum recommended pump speed

130 cycles per minute 5 gpm

130 cycles per minute 19 lpm

 

 

 

Wetted Parts

Steel, aluminum, buna-N, urethane

 

 

Sound pressure level (measured at 1 meter

77.8 dB(A)

from unit)

 

 

 

 

Sound power level (tested in accordance with

85.6 dB(A)

ISO 9614-2)

 

 

 

 

 

Approximate weight

17 lb

7.7 kg

 

 

 

Loctite® is a registered trademark of the Loctite Corporation.

(m3/min)

14

306518ZAC

Page 14
Image 14
Graco 306518ZAC Technical Data, tional ft3/min for each additional, additional m3/min for each, recommended range