Troubleshooting

Troubleshooting

1.Relieve the pressure. WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

1.Relieve the pressure.

2.Check all possible problems and solutions before disassembling pump.

Problem

Cause

Solution

 

 

 

Pump fails to operate.

Restricted line or inadequate air

Clear; increase air supply.

 

supply.

 

 

 

 

 

Insufficient air pressure; closed or

Open; clean.

 

clogged air valves, etc.

 

 

 

 

 

Exhausted fluid supply.

Refill; purge all air from pump and

 

 

fluid lines.

 

 

 

 

Damaged air valving mechanism;

Service air motor (see 306982 or

 

stalling.

307043).

 

 

 

 

Dried fluid seizure of displacement

Clean, check, or replace throat

 

rod (13).

packings (5, 24); always stop pump

 

 

at bottom of stroke and keep wet-

 

 

cup filled with compatible solvent.

 

 

 

Pump operates but output is low on

Restricted line or inadequate air

Clear; increase air supply.

both strokes.

supply.

 

 

 

 

 

Insufficient air pressure; closed or

Open; clean.

 

clogged air valves, etc.

 

 

 

 

 

Exhausted fluid supply.

Refill; purge all air from pump and

 

 

fluid lines.

 

 

 

 

Clogged fluid line, valves, etc.

Clear.*

 

 

 

 

Packing nut (2) too tight.

Loosen (see page 9).

 

 

 

 

Loose packing nut (2) or worn throat

Tighten packing nut (see page 9);

 

packings (5, 24).

replace throat packings.

 

 

 

Pump operates but output is low on

Held open or worn intake valve.

Clear; service.

downstroke.

 

 

 

 

 

Pump operates but output is low on

Held open or worn fluid piston valve

Clear; service.

upstroke.

or packings (20, 23).

 

 

 

 

Erratic or accelerated operation.

Exhausted fluid supply.

Refill; purge all air from pump and

 

 

fluid lines.

 

 

 

 

Held open or worn intake valve.

Clear; service.

 

 

 

 

Held open or worn fluid piston valve

Clear; service.

 

or packings (20, 23).

 

 

 

 

*To determine if the fluid hose or gun is obstructed, follow the Pressure Relief Procedure on page 8. Discon- nect the fluid hose and place a container at the pump fluid outlet to catch any fluid. Turn on the air just enough to start the pump (about 20--40 psi [0.1--0.3 MPa, 1.4--2.8 bar]). If the pump starts when the air is turned on, the obstruction is in the fluid hose or gun.