Graco 308116T System Accessories, Installation, Mounting Accessories, Air and Fluid Hoses

Models: 308116T

1 26
Download 26 pages 26.19 Kb
Page 7
Image 7
System Accessories

Installation

NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing.

If you supply your own accessories, be sure they are adequately sized and pressure--rated to meet the system’s requirements.

The Typical Installation shown on page 5 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs.

System Accessories

Refer to the Typical Installation on page 5.

Mounting Accessories WARNING

A bleed--type master air valve (D) and a fluid drain valve (J) are required in your system. These acces- sories help reduce the risk of serious bodily injury including fluid injection, splashing in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump.

The bleed--type master air valve relieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump.

The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient.

Mounting Accessories

Mount the pump (A) to suit the type of installation planned. Refer to the Dimensions and Mounting Hole Layout page 24.

Air and Fluid Hoses

Be sure all air and fluid hoses are properly sized and pressure--rated for your system. Use only grounded air and fluid hoses. Fluid hoses must have spring guards on both ends.

Connect a grounded fluid hose (L) to the pump’s fluid outlet.

Connect a fluid suction hose (N) to the pump’s 3/4 npt(f) fluid intake.

Use a grounded 1/2 in. I.D. (minimum) air hose (H) to supply air to the pump.

Air Line Accessories

Install the following accessories in the order shown in the Typical Installation, using adapters as necessary:

An air line lubricator (C) provides automatic air motor lubrication.

A bleed--type master air valve (D) is required in your system to relieve air trapped between it and the air motor when the valve is closed (see the Warning at left). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air regulator.

A pump runaway valve (B) senses when the pump is running too fast and automatically shuts off the air to the motor. A pump which runs too fast can be seriously damaged.

An air regulator (E) controls pump speed and outlet pressure by adjusting the air pressure to the pump. Locate the regulator close to the pump, but upstream from the bleed--type master air valve.

An air line filter (F) removes harmful dirt and mois- ture from the compressed air supply.

A second bleed--type air valve (G) isolates the air line accessories for servicing. Locate upstream from all other air line accessories.

Fluid Line Accessories

Install the following accessories in the positions shown in the Typical Installation, using adapters as neces- sary:

A fluid drain valve (J) is required in your system to relieve fluid pressure in the hose and gun (see the Warning at left). Install the drain valve pointing down, but so the handle points up when opened.

A fluid filter (K) filters harmful particles from the fluid.

A spray gun (M) dispenses the fluid. The gun shown in the Typical Installation is an airless spray gun.

308116 7

Page 7
Image 7
Graco 308116T System Accessories, Installation, Mounting Accessories, Air and Fluid Hoses, Air Line Accessories