![Technical Data](/images/new-backgrounds/32772/3277243x1.webp)
Technical Data
10:1 President
Category | Data |
|
|
Maximum fluid working pressure | 1800 psi (12.5 MPa, 125 bar) |
|
|
Maximum air input pressure | 180 psi (1.3 MPa, 12.5 bar) |
|
|
Pump cycles per 1 gallon (3.8 liters) | 20 |
|
|
Maximum recommended pump speed for continuous | 60 cycles/min |
operation |
|
Maximum flow at continuous duty | 3 gallon (11.4 liters) at 60 cycles/min |
Recommended speed for optimum pump life | |
|
|
Air consumption | approx. 15 scfm (0.42 m3/min) at 1 gpm (3.8 liters/min) |
| at 100 psi (0.7 MPa, 7 bar) air pressure |
|
|
Weight | approx. 31 lb (14 kg) |
|
|
Wetted parts | AISI 302, 303, 304, 316, and |
| Stainless Steel; Chrome Plating; PTFE; |
| Molecular Weight Polyethylene |
KEY: Fluid Outlet Pressure | A 180 psi (1.3 MPa, 12.5 bar) air pressure |
Air Consumption | B 100 psi (0.7 MPa, 7 bar) air pressure |
| C 70 psi (0.5 MPa, 4.9 bar) air pressure |
| D 40 psi (0.3 MPa, 2.8 bar) air pressure |
cycles per min |
| 20 | 40 | 60 | 80 | 100 | ||
psi | 1800 |
|
|
|
|
|
| scfm |
|
|
|
|
|
| m#/min | ||
bar | 125 |
| A |
|
|
|
| |
| 1600 |
|
|
|
|
| 80.0 | |
|
|
|
|
|
|
| 2.240 | |
| 110 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| 1400 |
|
|
|
|
|
| 70 |
|
|
|
|
|
|
| 1.960 | |
| 96 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| 1200 |
|
|
|
|
|
| 60 |
|
|
|
|
|
|
| 1.680 | |
| 84 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| 1000 |
|
|
|
|
|
| 50 |
|
|
|
|
|
|
| 1.400 | |
| 70 |
| B |
|
|
|
| |
|
|
|
|
|
|
| ||
| 800 |
|
|
|
|
|
| 40 |
|
|
|
| A |
|
| 1.120 | |
| 56 |
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
| 600 |
| C |
|
|
|
| 30 |
|
|
|
|
|
| 0.840 | ||
| 42 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| 400 |
|
|
| B |
|
| 20 |
|
|
|
|
|
| 0.560 | ||
| 28 |
| D |
| C |
|
| |
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||
| 200 |
|
|
| D |
|
| 10 |
|
|
|
|
|
| 0.280 | ||
| 14 |
|
|
|
|
|
| |
| 0 |
|
|
|
|
|
|
|
gpm | 0 |
| 1 | 2 | 3 | 4 | 5 | |
|
|
|
|
|
|
| ||
liters/min |
|
| 3.8 | 7.6 | 11.4 | 15.2 | 19.0 |
FLUID FLOW (TEST FLUID: NO 10 MOTOR OIL)
To find Fluid Outlet Pressure (bar/psi) at a specific fluid flow (lpm/ gpm) and operating air pressure (bar/psi):
1.Locate desired flow along bottom of chart.
2.Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale and read fluid outlet pressure.
To find Pump Air Consumption (m#/min or scfm) at a specific fluid flow (lpm/gpm) and operating air pressure (bar/psi):
1.Locate desired flow along bottom of chart.
2.Follow vertical line up to intersection with selected air consump- tion curve (gray). Follow right to scale and read air consumption.