General Description
The CycleFlo II is a pneumatic pump controller that allows precise control over the cycle rate of the pump and therefor the flow rate.
The pump cycle is initiated by a 120 volt signal. The pump cycle may be initiated by some other piece of equipment such as a timer or a pH controller. An isolation relay may be required in some installations. Always follow local and applicable electrical codes. The CycleFlo II will halt the pump cycle whenever the 120 volt signal is removed.
Installation
Electrical Connections
An access hole with a strain relief installed has been provided for the external power connection. Due to the unique requirements of each installation, access holes have not been provided for the other optional external wiring
connections such as the external air supply valve signal. Have a qualified electrician determine the proper strain relief, wire type, and wire size for your particular application. When positioning or adding access holes, be careful not to damage any internal components. Failure to use the proper strain relief, wire type and wire size can cause damage to internal components or personal injury.
There are three connections on the 120V input signal terminal block (see Fig. 1). The two right- hand connections are for line and neutral wires respectively. The
•A qualified electrician must complete all grounding and wiring connections and check the resistance.
•Refer to your local code for the requirements for a “true earth ground” in your area.