Operation

Priming the Pump

Prime the pump by applying a 120 Volt signal to the controller to allow the temporary operation of the pump. This cycle rate may be increased or decreased to facilitate pump priming. Shut off electrical supply before making adjustments.

Operation Procedures

The controller and pump are now ready for operation. The pump will cycle at the preset rate any time a 120 Volt signal is supplied to the controller.

Troubleshooting

The following is a list of possible problems and their causes.

Problem

 

Possible Cause & Remedy

No operation at all

1.

No power to the CycleFlo – check power source to unit.

 

2.

Damaged cycle rate adjustment relay – replace.

 

3.

No or low air supply – check air supply to make sure there is

 

 

sufficient pressure and air available.

 

4.

Bad wire connections – turn off power and check wire connections

 

 

from time delay relay to make sure they are all connected and

 

 

seated properly.

 

5.

Bad solenoid valve(s) – turn off air supply and listen for ‘clicking’ on

 

 

solenoid valves; replace valves if no ‘clicking’ is audible.

 

 

Pump only operates on one side /

1. Bad solenoid valve. Turn off and replace.

diaphragm.

2.

Damaged cycle rate adjustment relay.

 

 

 