Setup
Setup
1. Close fluid valves A and B.
TI2411A
2. Connect A (ISO) and B (RESIN) fluid hoses to fluid
manifold.
B (RESIN)
TI2417A
A (ISO)
3. Engage piston safety lock.
TI3850a
4. Connect the airlines, see Installation page 8.
Attach fluid manifold (D) to gun.
M
TI4764A
To change position of fluid manifold or use optional fluid inlets, see Fusion Gun manual 309856 or 309550.
5. For Mechanical Purge Guns Only:
a. Open clean off air line valve. Air should flow from air cap around Ceram Tip (M).
b. Open clean off air valve (K) about 1/4 to 1/2 turn, then adjust air flow as required.
c. Adjust purge rod, see manual 309856.
d. Go to step 10.
K
M
TI4765A
For Air Purge Guns Only:
a. Open clean off air line valve. Air should flow from nozzle (N). Continue through steps below.
N | TI4766A |
6. Disengage piston safety lock.
310649C | 11 |