Setup
312759R 23
Overview
There are five Edit screens. Edit Screen #1 is the Shot
Editing screen and Edit Screens #2-#5 are Sequence
Editing screens. Edit Screen #1 shows Shot #1 through
Shot #50. Each shot has a defined shot size that is mea-
sured in grams.
Edit Screens #2-#5 show Sequence A through
Sequence G. Each sequence has ten positions; shown
as A0 to A9 in FIG. 10. Each of the ten positions in the
sequence uses one of the Shot Numbers (GD) defined
in Edit Screen #1. The third column in FIG. 10 shows the
shot sizes (GE) for the selected Shot Numbers.
When operating in Sequence mode and a shot in the
sequence is finished, the machine will automatically
select the next position in the sequence that uses a Shot
Number with a non-zero shot size.
When operating in Sequence mode, there is an option to
allow the machine to automatically perform all of the
shots in the sequence with a preset delay between
shots. The delay between Shots(GF) is shown in the
fourth column. This process is called Auto-Sequencing.
Edit Shot Size
To edit the defined shot size(GE) for a certain shot
number using Edit Screen #1, use the following proce-
dure.
1. Navigate to the Edit Screen #1. See Screen Navi-
gation Diagram, page 16.
2. Press the Enter/Exit Screen button (GA) to enter the
screen.
3. Use the arrow keys to navigate to the shot size for
the Shot Number to be changed.
4. Use the numeric keypad to enter the desired shot
size in grams.
5. Press the Enter button ( ) to accept the shot
size and exit editing mode.
6. Press the Enter/Exit Screen button (GA) to exit the
screen.
Edit Shot Sequence
To change which Shot Numbers (GD) from Edit Screen
#1 are used in a sequence, use the following procedure.
1. Navigate to the Edit Screen that contains the
Sequence to be changed. See the list below, then
see Screen Navigation Diagram, page 16.
Sequences A and B are on Edit Screen #2
Sequences C and D are on Edit Screen #3
Sequences E and F are on Edit Screen #4
Sequence G is on Edit Screen #5
2. Press the Enter/Exit Screen button(GA) to enter the
screen.
3. Each Sequence Position(GC) uses a Shot
Number (GD). Use the arrow keys to navigate to the
Shot Number for the sequence position to be
changed.
4. Press the Enter button ( ) to enter editing
mode.
5. Use the Up Arrow button ( ) or the Down Arrow
button ( ) to change the Shot Number.
6. Press the Enter button ( ) to accept the Shot
Number and exit editing mode.
FIG. 11: Edit Shot Number in Sequence
Only Shot Numbers with non-zero shot sizes will be
available for selection.
GA
GC GD