Setup
312759R 35
System Data Screen
Software Version
Software version will read “0.00.000” if component can-
not be seen by the ADM. This is the result of the compo-
nent not being installed or a communication error.
Machine Cycles
A machine cycle is one full extension and retraction of
the machine piston. The Current Machine Cycles Coun-
ter is resettable and the Total Machine Cycles Counter is
the number of cycles since the ADM was installed.
Reprogramming the ADM will not reset the Total
Machine Cycles counter.
Reset Current Machine Cycles Counter
1. Press the Enter/Exit Screen button (MA) to enter the
screen. The Current Machine Cycles count will be
highlighted.
2. Press the Enter button ( ) to reset the Current
Machine Cycles counter.
3. Press the Enter/Exit Screen button (MA) to exit the
screen.
FIG. 21
Key:
MA Enter/Exit Screen
MB Cu rrent Machine Cycles Counter
MC Total Machine Cycles Counter
MD Advanced Display Module Software
Vers ion
ME Flui d Control Module #1 Software
Vers ion
MF Fluid Control Module #2 Software
Vers ion
MG Temperature Control Module -
Zone #1 Software Version
MH Temperature Control Module -
Zone #2 Software Version
MJ Temperature Control Module -
Zone #3 Software Version
MK Temperature Control Module -
Zone #4 Software Version
ML Active Screen Name
MM Adjacent Screen Names
MN Resettable material weight counter
MP Non-resettable material weight
counter