Operation

10.Turn prime valve horizontal. Trigger gun into flushing pail to purge fluid from hose.

11.Engage trigger lock.

20 s

ti24649a

12.Turn pressure control knob to the lowest pressure setting and turn ON/OFF switch to OFF position. Disconnect power to sprayer.

ti24717a

13.Remove filter from gun and sprayer if installed. Clean and inspect. Install filter. See separate gun manual.

28

ti24718a

14.If flushing with water, flush again with mineral spirits or Pump Armor to leave a protective coating to prevent freezing or corrosion.

ti24719a

15.Wipe sprayer, hose and gun with a rag soaked in water or mineral spirits.

ti24720a

334466A

Page 28
Image 28
Graco 334466A important safety instructions Ti24719a