Pressure Control

Control Board

Removal

WARNING

Read Injection Hazard, page 3; Burn Hazard, page 4

1.Relieve pressure, page 5.

2.FIG. 13. Remove two screws (91) and swing down cover (77)

3.Remove strain relief bushing (24a).

4.Disconnect engine and ground wires.

5.Disconnect at control board (90):

• Lead (D) from potentiometer

Lead (E) from transducer

Lead (B) from ON/OFF switch

Clutch wires

6.Remove four screws (89) and control board (90).

Installation

1.FIG. 13. Install control board (90) with four screws (89).

2.Connect at control board (90):

Clutch wires

Lead (B) from ON/OFF switch

Lead (E) from transducer

Lead (D) from potentiometer

3.Connect engine and ground wires.

4.Install strain relief bushing (24a).

5.Swing up cover (77) and secure with two screws (91).

Pressure Control Transducer

Removal

WARNING

Read Injection Hazard, page 3; Burn Hazard, page 4

1.Relieve pressure, page 5.

2.FIG. 13. Remove two screws (91) and swing down cover (77)

3.Disconnect lead (E) from control board (90).

4.Pull transducer connector through rubber grommet (78).

5.Remove pressure control transducer (20) and o-ring (63) from filter housing (30).

Installation

1.FIG. 13. Install o-ring (63) and pressure control transducer (20) in filter housing (30). Torque to 35 - 45 ft-lb.

2.Install transducer connector and rubber grommet in control housing.

3.Connect lead (E) to control board (90).

4.Swing up cover (77) and secure with two screws (91).

Pressure Adjust Potentiometer

Removal

WARNING

Read Injection Hazard, page 3; Burn Hazard, page 4

1.Relieve pressure, page 5.

2.Fig. 13.Remove two screws (91) and swing down cover (77).

3.Disconnect lead (D) from control board (90).

4.Loosen set screws on potentiometer knob (68) and remove knob, shaft nut, lock washer and potentiometer (70).

5.Remove seal (69) from potentiometer.

Installation

1.Install seal (69) on potentiometer (70).

2.FIG. 13. Install potentiometer, shaft nut, lock washer and potentiometer knob (68).

a.Turn potentiometer shaft clockwise to internal stop. Assemble potentiometer knob (68) to strike pin on cover (77).

b.After adjustment of step a., tighten both set screws in knob 1/4 to 3/8 turn after contact with shaft.

3.Connect lead (D) to control board (90).

4.Swing up cover (77) and secure with two screws (91).

310813 Rev C