INSTALLATION & PREPARATION INSTRUCTIONS

Initial Setup

Read safety warnings before setting-up air compres- sor. The following information contains operating and maintenance instructions.

Ensure the oil level in the air compressor pump is ad- equate. If low, add sae 30w non-detergent oil.

NOTICE

In order to avoid damaging the air compressor, do not incline the air compressor transversely or longitudinally more than 10°.

Place air compressor at least 12 inches away from ob- stacles that may prevent proper ventilation.

Do not place air compressor in an area:

Where there is evidence of oil or gas leaks.

Where flammable gas vapors or materials may be present.

Where air temperatures fall below 32°F or exceed 104°F.

Where extremely dirty air or water could be drawn into the air compressor.

Do not operate in an enclosed area. Use this product only in well ventilated areas. Exhaust from the engine contains carbon monoxide, a poisonous orderless and invisible gas. Breathing the gas can cause serious in- jury, illness and possible death.