Remove the Alternator
Remove the Alternator
1.Shut off the system’s main air valve. Open the con- trol box.
2.See FIG. 1. Disconnect output power cable connec- tions from alternator module (A). Disconnect ground lead (G) from control box ground terminal (T).
3.Disconnect the power supply cables from the Advanced Fluid Control Module (AFCM), USB Module, and Display Module.
4.Systems with a USB Module: Disconnect and save the cable (412) that runs from the AFCM to the alternator.
5.Disconnect air regulator line and exhaust air line from alternator module. Remove air regulator assembly (R) from solenoid manifold (M). Install plug (408) from kit in the open manifold port.
6.Remove four screws (S) from mounting to remove alternator from control box.
T | Air regulator |
| line |
A |
|
Cable | A |
connectors |
|
R
ti16456ati16455a
M | Install plug (408) | G | S | Air exhaust |
| in open port |
|
| line |
FIG. 1. Remove Alternator Module