Install the Power CAN Cables

Systems with a USB Module

1.See FIG. 3. Connect cable (413) to J6 of the display module and to connector P3 of the USB module.

2.Connect saved cable (412) to connector P4 of the USB module and to J8 of the Advanced Fluid Con- trol Module.

3.Connect the power supply CAN cable (C, FIG. 2) to J7 on the Advanced Fluid Control Module (FIG. 3).

4.See your ProMix 2KE Operation manual for instruc- tions on using the USB module.

USB Module (if present)

P4

P3

Connect cable

Connect cable

(412) here

(413) here

 

TI16580a

 

Display Module

TI16604a

J6

Connect cable (413) here

Install the Kit

Systems without a USB Module

1.See FIG. 4. Connect cable (413) to J6 of the display module and to J8 of the Advanced Fluid Control Module.

2.Connect the power supply CAN cable (C, FIG. 2) to J7 on the Advanced Fluid Control Module (FIG. 4).

Display Module

TI16604a

J6

Connect cable (413) here

Advanced Fluid Control Module

J8

J7

Connect

Connect

cable

cable (C)

(413) here

here

Advanced Fluid Control Module

TI16579a TI16602a

J8

Connect cable (412) here

FIG. 4. Install Power CAN Cables (without USB Module)

J7

Connect cable (C) here

TI16579a TI16602a

FIG. 3. Install Power CAN Cables (with USB Module)

3A1324B

5