Graco 965477, 965478, 965481, 965479, 965466 Troubleshooting Chart, Problem, Cause, Solution, 684025

Models: 965466 965479 965481 965478 965477

1 22
Download 22 pages 7.68 Kb
Page 15
Image 15

Troubleshooting Chart

PROBLEM

CAUSE

 

 

SOLUTION

System will not run or

Air

pressure or

air

Increase air pressure. Check air compressor and air supply filters

stops while running.

volume is too low.

regulator, lubricator valves and other components for blockages

 

 

 

 

 

and restrictions. If this is a new system, be sure that air supply

 

 

 

 

 

components have been sized properly.

 

The

fluid

valves or

Check the gun, fluid hoses, mix manifold, static mixer, fluid filters,

 

hoses are closed or

regulators, valves and other fluid line components for blockages

 

restricted.

 

 

and restrictions. If this is a new system, be sure that the fluid

 

 

 

 

 

components have been sized properly.

 

The

air

motor

is

Service the air motor. See “servicing the Air Motor” on page 17.

 

worn or damaged.

 

 

The displacement

See troubleshooting techniques below to isolate the problem

 

cylinder(s) is

 

cylinder. See “Service the cylinders” on page 16.

 

damaged or has

 

 

 

seized

 

 

 

The fluid pressure

Air

volume is

too

Verify that air pressure at the air motor inlet is not dropping during

bounces significantly

low.

 

 

 

pump changeover. Check air compressor and air supply filters

(>500 psi) while pump is

 

 

 

 

regulator, lubricator valves and other components for blockages and

running

 

 

 

 

restrictions. If this is a new system, be sure that air supply

 

 

 

 

 

components have been sized properly. 1” NPT hoses, fittings and

 

 

 

 

 

accessories are required to provide the necessary air volume.

 

Feed pump

 

Reduce feed pump pressure. Feed pump pressures must be less

 

pressure is too

 

than 25% of proportioner output pressure.

 

high.

 

 

 

 

The displacement

See troubleshooting techniques below to isolate the problem

 

cylinder(s) check

cylinder. See “Service the cylinders” on page 16.

 

valves are not

 

 

 

seating.

 

 

 

Mix ratio test is

Mix ratio test was

Perform ratio test again following ratio test procedure on page 12.

significantly different from

not performed at

 

 

the mix ratio setting.

the normal

 

 

 

operating pressure

 

 

of the pump

 

 

 

Running out of one

Check and refill material reservoirs. Repeat the test after the air has

 

material.

 

 

been removed from the system.

 

The displacement

See troubleshooting techniques below to isolate the problem

 

cylinder(s) are worn

cylinder(s). See “Service the cylinders” on page 16.

 

or the check valves

 

 

are not seating.

 

 

Spray output is spitting

Running out of one

Check and refill material reservoirs. Remember that once air is in

 

material.

 

 

the fluid system it may take a while for all of it to escape..

 

Siphon hoses

are

Tighten and seal all siphon fittings on proportioning pump and feed

 

leaking in air.

 

pumps.

A squeaking or knocking

The

bearings

are

Lubricate the bearings or replace them if required. See “service the

noise is heard.

dry or worn.

 

bearings” on page 18.

The proportioner speeds

Running out of one

Check and refill material reservoirs.

up or runs erratically

material.

 

 

 

 

The

cylinders

are

See troubleshooting techniques below to isolate the problem

 

worn or damaged.

cylinder(s). See “Service the cylinders” on page 16.

684025 15

Page 15
Image 15
Graco 965477, 965478, 965481, 965479, 965466 manual Troubleshooting Chart, Problem, Cause, Solution, 684025