KEY
ABleeder Type Main Air Valve
B Air Regulator
CPressure Relief Valve
DMix Manifold
EAir Supply Line
FAir Line Filter
GAir Shutoff Valve
HAir Line Lubricator
JBase Supply Pump
KCatalyst Supply Pressure Pot
LSolvent Supply Pump
MMix Manifold Flush Inlet
NStatic Mixer
PPrimary Pump Inlet
RSecondary Pump Inlet
SRatio Adjustment Screw
TSpray Gun
URatio Indicator Plate
VRatio Indicator Pin
Fig. 2 Typical Installation
System Accessories
Refer to Fig. 2.
NOTE: To ensure the maximum pump performance and safety, be sure that all the accessories used are properly sized to meet your system requirements and the pressure limits of the pump. Use only genuine Graco parts and accessories.
In the air line, install an air filter (F) to remove harmful dirt and moisture from the compressed air supply. Install an air line lubricator (H) downstream from the air filter, the air regulator (B) and the
WARNING
A
Connect the Air Supply Line
Connect an electrically conductive air supply hose to the 3/4” npt(f) port of the air manifold (B). Open the
Pressure Relief Valve
All components have rated working pressures of 5000 psi (345 bar) or greater. For more information about the pressure relief valve, see instruction manual 308547.
684025 7