Technical Data

Technical Data

Maximum Fluid Working Pressure

 

G3000 and G3000HR

4000 psi (28 MPa, 276 bar)

G250 and G250HR

250 psi (1.72 MPa, 17.2 bar)

 

 

Flow Range

 

G3000 and G250

0.02-1.0 gal/min (75-3800 cc/min)

G3000HR and G250HR

0.01-0.5 gal/min (38-1900 cc/min)

 

 

Fluid Temperature Range

40-180°F (4-80°C)

 

 

Maximum Ambient Temperature

180°F (80°C)

Fluid Viscosity Range

20-3000 cps (see Pressure Drop Curve on page 17)

Maximum Cable Length

200 ft (61 m)

 

 

Flow Meter Inlet/Outlet

1/4 npt(f)

Resolution

 

G3000 and G250

0.119 cc/pulse

G3000HR and G250HR

0.061 cc/pulse

 

 

Accuracy

+/- 0.5%*

 

 

Supply Voltage

10-30 Vdc

Intrinsic Safety

Class I; Div. 1; Group D

 

V max = 30 V

 

I max = 15 mA

 

Ci = 0.2 microfarads

 

Li = 0 mH

 

 

Approvals

See front cover

 

 

Wetted Parts

303 Stainless Steel, Tungsten Carbide, PTFE

Weight

 

G3000 and G3000HR

6 lb (2.7 kg)

G250 and G250HR

2.6 lb (1.8 kg)

 

 

*For most commonly used coatings, the flow meter reading will be accurate to within +/- 0.5%. Accuracy will dimin- ish at low viscosities and low flow rates.

16

308778L

Page 16
Image 16