14540 |
Sample
31 Point Series Progressive System
DESCRIPTION
■System Lube Volume: 6.0 cu in (99 cc) per hour
■
■Master Divider Volume per Cycle: .15 cu in (2.4 cc)
■Cycle Interval 15 Minute (1/4 hour) Used
■Volume per Lube Cycle: 6.0 cu in/4 = 1.5 cu in/15 min.
■Master Divider Cycles/Lube Cycle: 1.5 cu in/.15 cu in = 10 cycles
■Cycle Switch Transitions (2 transitions/cycle) x 10
=20
■Pump Strokes per Lube Cycle: 1.5 cu in/.24 cu in
=6.3 (use 7)
■Monitor Time: 7 Strokes x 6 seconds/stroke (3 second "ON", 3 second "OFF") = 42 second x 2 (safety factor) = 84 seconds.
PUMP AND RESERVOIR
MASTER DIVIDER VALVE
CYCLE SWITCH
LARGE BEARINGS
SECONDARY DIVIDER
VALVES
PROGRAMMING
1.Initiate Programming Mode
a)Press “PRGM” Key – “ON” Icon blinks
2.“ON” (Monitor Period)
a)Press “ENTER” Key – ON TIME/COUNT blinks
b)Use S Key and X Key to set Monitor (“ON”) Time to 0084
c)Press “ENTER” Key to accept value; “SEC/MIN/HR/CNT” blinks
d)Use S Key to scroll through choices; select ” SEC”
e)Press “ENTER” Key to accept choice; “OFF” Icon blinks
3.“OFF” (Pause Time)
a)Press “ENTER” Key – OFF TIME/COUNTblinks
b)Use S Key and X Key to set “OFF TIME” to 0015
c)Press “ENTER" Key to accept value; "SEC/MIN/HR/CNT" blinks
d)Use S Key to scroll through choices; select “MIN”
e)Press “ENTER” Key to accept choice; “CYCLE” Icon blinks
4.“CYCLE” (Cycle Switch Transitions)
a)Press “ENTER” Key; CYCLE (switch transitions) blinks
b)Use S Key and X Key to select 20 (20 cycle switch transitions = 10 Divider cycles)
c)Press “ENTER” Key to accept value; ”PUMP” Icon blinks
5.“PUMP ON” (Pump Duty-Pulsed/Non-Pulsed)
a)Press “ENTER” Key –
“PUMP” (pulsed on time) blinks
b)Use S Key and X Key to set ” ON TIME” TO 03 (3 sec pulsed output)
c)Press “ENTER” Key to accept value; LCD returns to “DISPLAY” mode
Programming is now complete. To verify lube se- quence, initiate a manual lube cycle by pressing “MANUAL RUN” button.
NOTE: If an electric motor driven pump or self cycling barrel pump is used, enter “00” in Step 5b for
Page 5