Installation
5
Installation

General Information

•FIG.3 on page 8 is only a guide for installing system
componentsand accessories. Itis notan actual sys-
tem design. Contact your Graco distributor for assis-
tance in designing a system to suit your particular
needs.
Always use Genuine Graco Parts and Accessories,
available from your Graco distributor. If you supply
your own accessories, be sure they are adequately
sized and pressure-rated for your system.
Referencenumbers and letters in parentheses refer
to the reference numbers in the figures and the
parts list on page 23.

Tighten Threaded Connections

1. Before each use, check all hoses for wear or dam-
age and replace as necessary.
2. Check to be sure all threaded connections are tight
and leak-free.
3. Check and re-torque all screws and fasteners at
least every two months. Re-torque the fluid cover
screws first, followed by the manifold screws. Note:
Before using pump, loosen fluid cover screws (31)
1-2 turns and then re-torque to 20 N•m (15 ft-lb).