Installation
6
Mounting the Pump
For ease of operation and service, mount the pump so
the air inlet, fluid inlet, and fluid outlet ports are easily
accessible.The inlet port must point down and the outlet
port must point up.
Use 5/8 in. lag screws or bolts for mounting.

Wall Mount Installation

1. Wall Mount Kit 245875 is available. See FIG.1.
2. Be sure the wall can support the weight of the
pump, bracket, hoses and accessories, as well as
the stress caused during operation.
3. Using the wall bracket (B) as a template, drill 5/8 in.
mounting holes in the wall. See page 27 for a wall
mountingdiagram. Mount the bracket 1.2-1.5 m (4-5
ft) above the floor.
4. Attach the bracket (B) to the pump (A) with the
screws (C) and washers (D) provided in the kit.
5. Attach the bracket to the wall. Use screws (E) that
are long enough to keep the pump from vibrating
during operation. Be sure the pump is level.

Floor Stand Installation

Floor Stand Kit 245874 is available. See FIG.2to
assemble.
To ensure proper operation, mount the pump in a
horizontal position.
FIG. 1: Wall Mount Kit
TI2079B
C
D
B
A
E
FIG. 2: Floor Stand Installation
TI20798